6.2
WORKING TIME MEMORIZATION with START control
To change the program of the control unit make as follow:
T ...
1
2
P1
P2
3
P3
4
P1
Set up Description
T 01
Opening time MOT1
T 02
Closing time MOT 1
T 03
Opening time MOT2
T 04
Closing time MOT2
T 05
Slow down when opening MOT 1
T 06
Alow down when opening MOT 2
T 07
Slow down when closing MOT1
T 08
Slow down when closing MOT2
T 09
Opening Desplacement
T 10
Closing Desplacement
T 11
Pause time for START
T 12
Opening time MOT1 PARTIAL OPENING time
T 13
Closing time MOT1 PARTIAL OPENING time
T 14
Pause time for PARTIAL OPENING
T 17
KEY LOCK function
T 19
Reversing stroke
T 20
Starting of MOT1 (when starting, the obsctacle detection is not available)
T 21
Starting of MOT2 (when starting, the obsctacle detection is not available)
7
Reset of the control unit at STANDARD VALUE
The control unit can bring back the standard value (see par. 8) to reset make as follow:
S 18
1
2
P1
3
P1
Press P2 and P3 until you will find T...
Press P1 to choose the set up
Press P2 and P3 to choose the value
Press P1 to confirm the operation
Press P2 and P3 until S18
Press P1 to confirm the operation
To cancel the operation
press P1 for 10 seconds
Values confirmed
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
(in advance) from 2 to 127,5 s
(in advance) from 2 to 127,5 s
(in advance) from 2 to 127,5 s
(in advance) from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 2 to 127,5 s
from 0 to 10 s
(0 for deactivation) from 0 to 10 s
from 0 to 10 s
from 2 to 10 s
Default
15 s
15 s
15 s
15 s
2 s
2 s
3 s
3 s
2 s
2 s
10 s
8 s
8 s
10 s
2 s
0 s
2 s
2 s
WARNINg!
This operation
cancel all
benchmarks
17