5. Electronic sensitivity enhancement setting [SENS UP]
Use of the electronic sensitivity enhancement function increases the quantity of light stored on
the CCD, and accordingly the image becomes brighter. The magnification is unchanged for
selection of FIX, and the magnification is changeable in accordance with the illuminance of a
subject for selection of AUTO. The magnification of the electronic sensitivity is selectable from
the following.
OFF (default)/X2 AUTO/X4 AUTO/X6 AUTO/X10 AUTO/X16 AUTO/X32 AUTO/X2 FIX/
X4 FIX/X6 FIX/X10 FIX/X16 FIX/X32 FIX/X64 FIX/X128 FIX
Notes:
• When the magnification of "SENS UP" is increased, the screen becomes coarser, more
whitish, or more flawed. However, this phenomenon is normal.
• The status display of the system device does not show "X64 FIX" and "X128 FIX" of "SENS
UP". In such cases, "X32 FIX" is shown.
33