Selection of using XON/XOFF function [XON/XOFF]

This setting allows users to choose whether or not to control data flow with use of XON/XOFF
code.
NOT USE (default setting): Data flow control with XON/XOFF code disabled
USE: Data flow control with XON/XOFF code enabled

Selection of data retransmission interval [WAIT TIME]

When data reception is not confirmed, the interval to retransmit the same data is selectable
from the following:
OFF (default setting)/100 ms/200 ms/400 ms/1 000 ms

Selection of alarm data transmission method [ALARM DATA]

The method of alarm data transmission at event occurrence is selectable from the following:
POLLING: Transmits the data when it is required from the controller.
AUTO1: Transmits the data when alarm signal input is provided.
AUTO2 (default setting): Transmits the data at intervals of 5 seconds.
Selection of period until transmission of data reception acknowl-
edgement (ACK) [DELAY TIME]
The period until transmission of data reception acknowledgement is selectable from the follow-
ing:
This period selection is displayed and available only when the "2-wire communication" method
is used.
OFF (default setting)/100 ms
Note:
• "---" is displayed when the "4-wire communication" method is used.