Connect the power cord and turn on the power.
WV-CLR930
Connect between the power connector on the rear side of the camera and a plug socket
with the supplied power cord.
220 to 240 V AC,
50 Hz
Caution:
The camera shall be connected with cord set with plug.
Plug for respective country shall be mounted on the Power cord by a qualified electrical.
WV-CLR934
Select either 24 V AC or 12 V DC for
power supply and connect the power
supply to the AC/DC power terminal.
Caution:
To prevent fire or electric shock haz-
ard, use a UL listed cable (VW-1, style
1007) for the 24 V AC or 12 V DC
Input Terminal.
m
Adjust the camera angle by loosening the screw of the camera mount bracket
while viewing the video monitor.
Be sure to loosen the screw of the camera mount bracket when the camera angle is adjust-
ed. If the camera angle is changed when the screw is tight, excessive force is applied to
the camera mount bracket and camera, and accordingly they may be damaged. Be sure to
tighten the screw securely after camera angle adjustment.
,
Adjust the focus.
When an auto iris lens is used, the originally adjusted focus may be slightly off depending
on the iris state resulting from the focal depth of the lens. In such a case, open the iris by
darkening the subject as much as possible and adjust the focus, and the focus-off state
can be prevented.
Power cord (accessory)
GEN-LOCK
220V-240V ~ 50Hz
IN/OUTPUT
TERMINAL
GEN-LOCK
AC 24V IN
DC 12V IN
IN/OUTPUT
1-L
TERMINAL
1
2
2-N
3
4
5
GND
+
–
12 V DC
or
24 V AC
VIDEO OUT
POWER
1
2
3
4
6
5
7
8
9
VIDEO OUT
POWER
6
7
8
9
15