Technical Data; Model Identification; Commissioning The Device; Operations Prior To Installation - Madas M16/RM N.A. Manual Del Usuario

Ocultar thumbs Ver también para M16/RM N.A.:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.0 - TECHNICAL DATA

• Use
• Ambient temperature
• Power voltages (see table 2a - 2b)
• Power supply tolerance
• Electric wiring
• Absorbed power
• Maximum operating pressure
• Closing time
• Protection rating
• Mechanical resistance
• Rp threaded connections
• Flanged connections to be coupled
with PN 16 flanges
• NPT threaded or ANSI flanged connections : on request
• In compliance with
* Only single-phase, the device does not work if powered with three-phase
** DN 25 with swivel flanges.

2.1 - MODEL IDENTIFICATION

M16/RM N.A.
: Normally open, manual reset solenoid valves for gas
MBA/RM N.A.
: Normally open, manual reset solenoid valves for gas, low absorption

3.0 - COMMISSIONING THE DEVICE

3.1 - OPERATIONS PRIOR TO INSTALLATION

• It is necessary to close the gas upstream of the valve prior to installation;
• Make sure that the line pressure DOES NOT EXCEED the maximum pressure declared on the product label;
• Any protective caps (if any) must be removed prior to installation;
• Valve pipes and insides must be clear of any foreign bodies;
If the device is threaded:
• make sure that the pipe thread is not too long, to prevent damaging the body of the device when screwing it on;
If the device is flanged:
• make sure the inlet and outlet counter-flanges are perfectly coaxial and parallel in order to prevent unnecessary
mechanical stress to the body. Also calculate the space to insert the seal gasket;
• With regard to tightening operations, equip yourself with one or two calibrated torque wrenches or other controlled
locking tools;
• The safety regulations on handling loads in force in the country of installation must be complied with. If the device to
be installed exceeds the weight allowed, suitable mechanical equipment and adequate slings must be used. Necessary
precautions must be taken during the handling phases so as not to damage/ruin the external surface of the device.
• In accordance with EN 161 a suitable filter must be installed upstream of a gas closing safety device;
• With outdoor installation, it is advisable to provide a protective roof to prevent rain from damaging the electrical parts of
the device.
• Prior to carrying out any electrical wiring operations, make sure that the main voltage matches the supply voltage indicated
on the product label;
M16/RM N.A. - MBA/RM N.A.
: non-aggressive gases of the three families (dry gases)
: -20 ÷ +60 °C
: 12 Vdc - 12 V/50 Hz - 24 Vdc - 24 V/50 Hz - 110 V/50-60 Hz - 230 V/50-60 Hz*
: -15% ... +10%
: cable gland M20x1.5
: see table 2a - 2b
: 500 mbar
: < 1 s
: IP65
: Group 2 (according to EN 13611)
: (DN 20 - DN 25 - DN 32 - DN 40 - DN 50) according to EN 10226
: (DN 25** - DN 32 - DN 40 - DN 50) ISO 7005 / EN 1092-1
: EMC Directive 2014/30/EU - LVD Directive 2014/35/EU
RoHS II Directive 2011/65/EU
10
voltage.
Madas Technical Manual - REV. 0 of 10
Oct 2018
th

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mba/rm n.a.

Tabla de contenido