Chapter IX Failures
Troubleshooting
Turntable rotating only in
one way
Turntable failure
Failure of turntable to
clamp the rim properly
Locking failure of square
shaft and hexagonal shaft
Failure of push-pull arm
Stagnation of hexagonal
shaft
Too fast or slow leaning or
returning of column
Returning failure of chassis
pedal
Motor failure or insufficient
output torque
I n s u f f i ci e n t o u t p u t o f
cylinder
62
AE1015/AE1015-3/AE1015H/AE1015H-3
Possible Reasons
Burnout of universal change-over switch contact
Belt damage
Belt too loose
Fault of motor or power supply
Damage of universal change-over switch
Tear of clamping jaw
Leakage of clamping cylinder
Locking plate not in place
Leakage of locking cylinder
Square locking plate not in the correct position
Hexagonal locking plate not in the right position
Too fast or slow exhaust of column cylinder; too low
air source pressure
Damage of pedal return torque spring
Jam of drive part
Capacitor breakdown
Insufficient voltage
Short circuit
Air leakage
Mechanical barrier
中文
EN
DE
RU
KO
Troubleshooting
Replace the universal change-over switch
Replace the belt
Adjust the belt tightness
Check the power wiring of motor, power supply
and junction box
Motor is burned out; replace the motor
Replace the universal change-over switch
Replace the clamping jaw
Replace the leaking seals
Regulate the adjustment screw of locking plate
Replace the sealing ring of cylinder
See Chapter V Maintenance
Adjust the square and hexagonal locking plates
Open the side panel and adjust the flow valve
according to (3.2.1) "ventilation test"
Replace the torque spring
Rectify the jamming point
Replace the capacitor
Wait for the voltage recovery
Unshorting
Replace the seals
Rectify the barrier
Adjust the pressure as required