OPERATING INSTRUCTIONS
Disconnecting A Liquid Propane
gaz propane liquide de votre gril :
Gas (LP Gas) Tank From Your Grill:
1. Tourner les boutons des brûleurs et la
1. Turn the burner knobs and LP gas
valve de la bouteille de gaz à la position
tank valve to the full OFF position.
OFF. (Tourner dans le sens horaire pour
(Turn clockwise to close.)
fermer.)
2. Détacher l'assemblage tuyau et
2. Detach the hose and regulator
régulateur de la valve de la bouteille de
assembly from the LP gas tank valve
propane liquide en tournant l'écrou de
by turning the quick coupling nut
raccord rapide dans le sens antihoraire.
counterclockwise. See Fig. 8.
Voir. Fig. 8.
CAUTION: When the appliance is
not in use, the gas must be turned
off at the supply tank
L.P. TANK INFORMATION
INFORMATION SUR LA BOUTEILLE DE PROPANE LIQUIDE
Never use a dented or rusted L.P. tank or cylinder with a damaged valve.
Ne jamais utiliser une bouteille de propane liquide rouillée, bosselée ou avec une valve endommagée.
L.P. cylinders are equipped with an O.P.D. (Overfilling Prevention Device). The device shuts off
the flow of gas to a cylinder after 80% capacity is reached. This limits the potential for release of
gas when the cylinder is heated, averting a fire or possible injury.
potentiel de dégagement de gaz quand la bouteille est chauffée, évitant ainsi les incendies et les
blessures éventuelles.
The L.P. cylinder must have a shut-off valve terminating in an L.P. gas supply cylinder outlet
specified, as applicable, for connection No. 510 in the standard for compressed gas cylinder
valve outlet and inlet connection ANSI/CGA-V-1. Cylinders must not be stored in a building,
garage, or any other enclosed area. (The L.P. cylinder must have an overfill protection device
and a collar to protect the cylinder valve.)
bouteille.)
The L.P. gas supply cylinder must be constructed and marked in accordance with the
specifications for L.P. gas cylinders of the U.S. Department of Transportation (DOT) or the
National Standard of Canada, CAN/CAS-B339, "Cylinders, Spheres and Tubes for the
Transportation of Dangerous Goods and Commission."
UTILISATION DE LA BOUTEILLE DE P.L.
L.P. TANK USE
When turning the L.P. tank on, make sure to open the valve SLOWLY two (2) complete
turns to ensure proper gas flow. Most gas tanks now come equipped with a leak
detector mechanism internal to the tank. When gas is allowed to escape rapidly it shuts
off the gas supply. Opening the valve rapidly may simulate a gas leak, causing the
safety device to activate, restricting gas flow causing low flames. Opening the valve
slowly will ensure this safety feature is not falsely triggered.
position OFF.
de vapeur.
.
Fig. 8