Prepare The Installation; Install Backsplash (Optional); Select Blower Option (Exterior Or Interior) - Broan best K210A Instrucciones De Instalación

Ocultar thumbs Ver también para best K210A:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2. PREPARE THE INSTALLATION

When performing installation, servicing or cleaning the unit, it is recommended to wear safety
glasses and gloves.
Make sure that the following items are included:
- Range hood
- Accessories:
• Filters
• Bag of parts including:
(4) lock nuts, (1) wire clamp, (8) 1/2" double thread screws, (2) wire connectors,
(2) 1/2" standard screws, (6) 3/8 screws.
Parts sold separately:
- Interior blower Model P5 includes blower, rough-in kit, flow deviator and 3¼" x 10" adapter
- Interior blower Model P8 includes blower, rough-in kit, flow deviator and 3¼" x 10" adapter and 3¼" x 14" adapter
- In-line blower assembly ILB3, ILB6, ILB9 or ILB11 (all include transition and rough-in plate)
- Exterior blower assembly EB6, EB9, EB12 or EB15 (all include rough-in plate)
- Shielded halogen lamps (120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base)
- Backsplash (optional)
- Baffle filters (optional)
- Transitions, duct, elbows, dampers, wall and roof caps. Refer to page 3 and 4 for a complete list of venting options
and model numbers.
NOTE: For cabinets with recessed bottom, attach wood filler strips (not included) on each sides, as shown below.
Use two (2) 2-inch wide strips for 30'' wide hoods, and four (4) 2-inch wide strips for wider hoods, cut to length.
See below for wood filler strip locations.
H
OOD
WIDTHS
30''
36''
42''
48''

3. INSTALL BACKSPLASH (OPTIONAL)

Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting
screws. In order to be able to install the backsplash, make sure you have at least 18'' clearance between bottom of
hood and range control panel or cooktop. (See instructions packed with backsplash.)

4. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR)

INTERIOR BLOWER:
EXTERIOR BLOWER:
CAUTION
L
OCATIONS
A
B
C
2''
/
/
N
A
N
A
2''
4½''
4½''
2''
7¼''
8¼''
4''
10¼''
11¼''
Follow all subsequent steps of this manual.
Refer to instructions packed with exterior blower and follow steps 6, 9, 10, 12 and up of
the present manual.
A
B
HD0079
- 6 -
A
C

Publicidad

Tabla de contenido