ply with local regulations in force and
must be periodically reviewed and/or
replaced in accordance with local
conformities in force, by authorized
personnel.
The outlet from the appliance is
"male" type and 1/2"G. The con-
nection pipe must be of "fema-
le" type and 1/2 "G as described by
local standards.
The pipes must be screwed fir-
mly to their attachment points.
Conduct a test to ensure that there
are no gas leaks once the network
gate valve is open (Fig. 4).
Upon completion of the operations descri-
be, close the network gate valve (Fig. 3).
If it is necessary to replace the
nozzle to conform to another
type of gas supply, see the pro-
cedure described in the Operations
for commissioning (see chapter 5).
GAS TYPE CHANGE - see SECT.
IMAGES - REF. f)
The appliance comes from the
factory with setting to the type
NEW! REMOVABLE BOTTOM / vd. SEZ. ILL - RIF. l)
In the models provided (free cupboard bottom), it is possible to remove the
lower surface for installation and maintenance operations (eg inspections, con-
nections, cleaning etc). To remove the bottom, unscrew and remove it (Part A).
To reposition the bottom, insert and screw again (Part B).
If there are doors, they must first be disassembled (hinges and fixing).
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
POWER SUPPLY CONNECTIONS
of power indicated on the plate. Any
other configuration that changes the
parameters set must be authorized
by the manufacturer or by its repre-
sentative.
The transformation from one
type of power to another must
be performed by qualified tech-
nical personnel authorized to per-
form the operation in question. The
correct procedure to be implemented
for the transformation is described in
the relevant manual.
Injectors - By Pass - Pilot injec-
tors - Apertures - and anything
necessary for any gas transfor-
mation must be requested directly
from the manufacturer.
At the end of the transformation
from one type of power to
another, change the label on the ap-
pliance with new the parameters re-
ported on the adhesive document
provided.
Two plates may need to be repla-
ced in certain cases (oven equi-
pment), one outside near the
gas attachment and one inside (see
image reference f).
- 11 -
4.