Idiomas disponibles

English
5.
Inspecting the screws
Regularly inspect each component of the power tool for looseness.
Re-tighten screws on any loose part.
WARNING:
6.
Inspecting the lower guard for proper operation
Before each use of the tool, test the lower guard (see Fig. 7) to assure that it is in good
condition and that it moves smoothly.
Never use the tool unless the lower guard operates properly and it is in good mechanical
condition.
7.
Storage
After operation of the tool has been completed, check that the following has been performed:
(1)
Trigger switch is in OFF position,
(2) Power plug has been removed from the receptacle.
(3) When the tool is not in use, keep it stored in a dry place out of the reach of children.
8.
Lubrication
Lubricate the following sliding surfaces once a month to keep the power tool in good operating
condition for a long time (see Fig. 1 and Fig. 2). Use of machine oil is recommended.
Oil supply points:
* Rotary portion of hinge
* Rotary portion of vise assembly
9.
Cleaning
Duct
Air gun
Fig. 42
36
To prevent personal injury, never operate the power tool if any
components are loose.
Lower guard
Dust port
Clean the machine, duct, dust port and lower
guard by blowing with dry air from an air gun or
other tool.
Periodically remove chips, dust and other waste
material from the surface of the power tool,
especially from the inside of the lower guard with
a damp, soapy cloth. To avoid a malfunction of
the motor, protect it from contact with oil or water.
If the LED light becomes invisible due to chips
and the like adhered onto the window of the
LED's light-emitting section, wipe and clean the
window with a dry cloth or a soft cloth moistened
with soapy water, etc.