Anexo D
D.1 Mensajes de error del SCALANCE X300 / X400
Mensajes de error asignados a un estado de error (LED de error)
Observer: RM signals active but RM test frames are received on both ring ports.
Observer: RM signals right state.
Observer: RM runs incompatible software version <número de versión>.
Observer: RM's incompatible software version <número de versión> disappeared.
Observer: RM test frame timeout on both ring ports.
Observer: RM test frames received.
Observer stopped recovering because of too many (<número de errores>) repeated errors.
Observer restarted because of user command.
Standby <partner / observer> conflicts with <active / passive> state.
Standby <partner's / observer's> state conflict resolved.
Standby <partner / observer> conflicts with <master / slave> role.
Standby <partner / observer> conflicts with <master / slave> role resolved.
Power down on line <ID de la fuente de alimentación>.
Power up on line <ID de la fuente de alimentación>.
Internal error: <tensión> V power down.
Internal error gone: <tensión> V power is back.
Wrong module <nombre de módulo> on slot <número de slot> (ID: <ID de módulo>).
Wrong module <nombre de módulo> on slot <número de slot> removed.
C-PLUG not accepted. See System C-PLUG mask for details.
C-PLUG accepted.
C-PLUG interface unmounted - restart required.
C-PLUG interface mounted.
C-PLUG missing.
C-PLUG found.
The media modul for ring <número de puerto> is missing.
The media modul for ring <número de puerto> was detected.
DIP switch <nombre del interruptor> changed, restart required.
DIP switch <nombre del interruptor> set back to original state.
Internal error(s) and/or exception(s) occurred.
Internal error(s) and/or exception(s) confirmed.
Device boot up incomplete.
Device boot up completed.
RM <dirección MAC> lost.
RM <dirección MAC> detected.
The media modul for standby <número de puerto> is missing.
The media modul for standby <número de puerto> was detected.
PNIO fault - please use STEP 7 for diagnostics
PNIO fault - gone.
PNIO connection established
PNIO connection terminated.
Severe module change detected, restart required.
Severe module change reverted.
DIP switch settings manipulated ... -> Redundancy will be started after next restart.
DIP switch settings reset ... -> Redundancy mode will not change after next restart.
Authentication status on <número de puerto>: FAILED! Reason: <causa del error>"
Authentication status on <número de puerto>: o.k. Reason: <causa del error>
348
Manual de configuración, 02/2012, C79000-G8978-C187-18
SCALANCE X-300 / X-400