Siemens SIMATIC NET SCALANCE X-300 Manual De Configuración página 351

Ocultar thumbs Ver también para SIMATIC NET SCALANCE X-300:
Tabla de contenido

Publicidad

Avisos informativos
(R)STP protocol disabled.
Disabled (R)STP because ring redundancy is enabled.
DIP settings taken from C-PLUG.
RM=<ON|OFF>, STBY=<ON|OFF>, R1=<ON|OFF>, R2=<ON|OFF>
(R)STP topology change detected while (R)STP is off. Aging time will be reduced to <tiempo en s>
sec for at least <tiempo en s> sec.
Set aging time back to original value <tiempo en s> sec.
No connection to SNTP server. Server IP address <dirección IP>.
Connected to SNTP server. Server IP address <dirección IP>.
Enabled link status monitoring on ring ports.
Changed port VLAN ID of the ring ports to 1.
Disabled GVRP because ring redundancy is enabled.
Disabled GMRP because ring redundancy is enabled.
Disabled mirroring because monitor port is ring port.
(Re)enabled ring ports (because disabled by user).
Disabled port lock on ring ports.
Warning: ring ports have different static VLAN configuration.
Warning: ring ports have different VLAN port configuration.
Warning: ring ports have different static multicast configuration.
Warning: ring ports have different load limits configuration.
Enter fault state: port <número de puerto> enabled for link status monitoring and link down.
Leave fault state: port <número de puerto> disabled for link status monitoring.
Enter fault state: power line <ID de la fuente de alimentación> enabled for power monitoring and
power down.
Leave fault state: power line <ID de la fuente de alimentación> disabled for power monitoring.
<CLI | WBM | SSH>: Authentication failure.
Warning: OSPF consumed too much memory and is shut down.
Duplicate IP address <dirección IP> sent from <dirección MAC>
IN <número de la entrada digital> (<nombre de la entrada>) <high o low>
VRRP: Virtual Router <número del router> on VLAN <ID de VLAN> transitioned to <Master | Backup
| Disabled | Initialize | Invalid> state.
PNIO configuration invalid, conflict with standby.
PNIO configuration invalid, conflict with HSR.
PNIO configuration invalid, conflict in MRP ring ports: <causa del conflicto>
PNIO configuration invalid, conflict in alternative redundancy configuration.
PNIO configuration invalid, conflict detected: <descripción del conflicto de configuración>
SCALANCE X-300 / X-400
Manual de configuración, 02/2012, C79000-G8978-C187-18
D.1 Mensajes de error del SCALANCE X300 / X400
Anexo D
351