Call-Up Of Calibration Menu; Flange Calibration - Bosch WBE 4510 Manual Original

Máquina de equilibrado de ruedas
Ocultar thumbs Ver también para WBE 4510:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 94
14.4
Calibration
i
As part of service and upkeep (every six months),
on flange replacement or in the event of measure-
ment inaccuracies, it is advisable to calibrate the
WBE 4510 in the following sequence:

1. Flange calibration.

2. Vernier caliper calibration.
3. WBE 4510 calibration.
4. Perform reference measurement.
14.4.1

Call-up of calibration menu

1. The menu is called up from the Service page <o>.
2. Enter the password: <r> <r> <o>.
"
The calibration menu is displayed.
i
Press <X> to exit from the calibration menu.
14.4.2
Flange calibration
i
Follow the instructions shown on the monitor.
1. Fit the flange (refer to Section 5).
i
Do not attach the wheel, do not use any clamping
tools.
2. Start flange calibration in the calibration menu.
Press <r> <r> and <OK>.
3. Press <OK>.
« The wheel guard closes automatically.
« The unbalance measurement commences auto-
matically.
"
Flange calibration completed.
"
Unbalance set to "0".
Robert Bosch GmbH
Maintenance | WBE 4510 | 61
14.4.3
Electronic vernier caliper calibration
i
Follow the instructions shown on the monitor.
1. Start calibration in the calibration menu. Press
<r><r><r> and <OK>.
2. Set the vernier caliper (B) to the rest position and
press <OK>.
3. Extend the vernier caliper (B) to 200 mm, enter this
value and press <OK>.
4. Clamp a test wheel in position (ideally 13" or 14").
5. Enter the wheel diameter and press <OK>.
6. Apply the vernier caliper (B) to the rim flange and
press <OK>.
"
Vernier caliper calibration completed
en
|
1 695 655 163
2010-07-17

Publicidad

Tabla de contenido
loading

Tabla de contenido