12 Technical Data

Operating pressure
Operating/water temperature
Ambient temperature
operation
during
storage/transport
Flow rate with 1 bar pressure loss
Empty filter cartridge volume
Weight (dry/wet)
Comparable capacity according to DIN 18879-1:2007
The comparable capacity is a standardised indicator to facilitate comparison of different fi lters. The comparable capacity is
determined under extreme conditions. The usable capacity in practical operation is higher than the comparable capacity and may
vary greatly depending on the usage conditions.
Comparable capacity
Dimensions complete system
(Width/Depth/Height)
The bending radii of the inlet and outlet hose 2 m, DN13, 3/4"–3/4" are approx. 130 mm and, depending on the installation
orientation and operating space, must be considered in addition to the dimensions of the complete system.
Operating position
Inlet connection
Outlet connection
* with ACS Technology

13 Order Numbers

Caution: The PURITY replacement cartridge may only be used in combination with the pressure
!
vessel that has been specifically designed for its size. See cover.
Filter system PURITY 450 Steam/PURITY 600 Steam/PURITY 1200 Steam
Article
PURITY 450 Steam
PURITY 450 Steam (Complete System with Filter Cartridge) with Measuring and Display Unit
PURITY 450 Steam (Complete System with Filter Cartridge)
PURITY 450 Steam Filter Cartridge
PURITY 600 Steam
PURITY 600 Steam (Complete System with Filter Cartridge) with Measuring and Display Unit
PURITY 600 Steam (Complete System with Filter Cartridge)
PURITY 600 Steam Filter Cartridge
PURITY 1200 Steam
PURITY 1200 Steam (Complete System with Filter Cartridge) with Measuring and Display Unit
PURITY 1200 Steam (Complete System with Filter Cartridge)
PURITY 1200 Steam Filter Cartridge
Filter system PURITY Steamwith filter cartridge
PURITY 450 Steam
distributor
MDU*
head
400 l/h
500 l/h
3,9 l
10 kg/12 kg
2754 l
249 mm/222 mm/408 mm 249 mm/222 mm/520 mm 288 mm/255 mm/550 mm
The filter system can be operated either vertically or horizontally.
PURITY 600 Steam
PURITY 1200 Steam
distributor
MDU*
MDU*
head
2 bar to max. 6,9 bar
4°C to 30°C
10°C to 40°C
–20°C to 50°C
400 l/h
500 l/h
400 l/h
5,8 l
12 kg/15 kg
4734 l
G 1"
G 3/4"
distributor
head
500 l/h
9,9 l
18 kg/24 kg
9521 l
EN
Article number
1002912
1000654
1000653
1002918
1000245
1000252
1002923
1000226
1000231
35