8 Move the torch out of the clamping device (1) and remove the distance sleeve (5) from the milling
cutter (6).
6.6 Adjusting the quantity of release agent.
Cleaning unit
1
Adjusting the quantity of release agent.
Fig. 8
For adjusting the spray quantity, the system must be provided with compressed air. In order to assess the
function and the spray quantity, the solenoid valve Y4 must be switched.
Danger of crushing
Limbs can be drawn in and crushed by turning parts (milling cutter, clamping unit, wire cutting device
(DAV)).
• Do not reach into turning parts.
Damage to the eyes
Sprayed release agent may damage the eyes.
• Wear safety goggles.
• Adjust release agent by switching the solenoid valve Y4 only.
1 Connect the connecting hose to the release agent bottle.
2 Adjust the quantity of release agent by means of the adjusting screw of the throttle (3).
We recommend you to screw in the adjusting screw of the throttle (3), rotating it three to six times.
NOTE
• In order to guarantee that the release agent is drawn in properly, the solenoid valve Y4 should be
1
Vacuum generator
2
WARNING
WARNING
switched for approx. 7 seconds before spraying with a new or recently filled bottle.
6 Putting into operation
2
3
Throttle
3