3.5.2

Parameters mode

PARAMETER
UP
DOWN
PROG
UP
next parameter
DOWN
previous parameter
+
increases the parameter value by 1
-
decreases the parameter value by 1
PROG
programming the stroke (see par. 4.1)
TEST
enables test mode (see par. 3.5.4)
3.5.2.1

Changing a parameter

Using the UP and DOWN buttons to view the
parameter to be changed, then with the + and -
buttons change its value (the number on the right
starts flashing).
While holding down a button, after one second
quick sliding is activated, allowing you to change
the parameter quicker. To save the value set on the
display, wait a few seconds, or move to another
parameter with the UP and DOWN buttons: the
whole display will flash quickly indicating that the
parameter has been saved.
NOTE: Changing the numerical value of the
parameters with the + and - buttons is only possible
with the engine stopped, while consultation of the
parameters is always possible.
The sequence of parameters in the mode simplified
is shown in the following page.
ATTENTION!
Some parameters (
critics, and change them with the system already
started,may cause malfunction; to give effect to the
change in their value you have to disconnect the
power supply and then restart the system and re-
programming the stroke
3.5.2.2
Restoring standard factory pa-
rameters
N.B.: this procedure is only possible if you have not
entered the password to protect your data.
Turn off the control unit, simultaneously press and
VALUE
TEST
0-
C-
and
) are particularly
hold the UP and DOWN buttons then turn on again
and keep up pressing the buttons: after 4 seconds
the display will show the writing
which indicates that the values have been restored.
N.B.: parameter
+
simplified mode) is not restored; it must always be
-
set manually.
3.5.2.3
The
control
configuration: extended or simplified.
In extended mode the installer can change a lot
of parameters, but you need a more in-depth
knowledge of the product.
Simplified mode has been designed for ease of
installation, only a few parameters can be changed.
It is the recommended mode for an installer who is
not very familiar with the product and who does not
need special configurations.
WARNING!
The product leaves the factory set in simplified
mode, with standard values which satisfy the
majority of installations.
If you want to go to extended mode hold the UP and
DOWN buttons both for 4 seconds, after this time
the first of the parameters of the extended version
will be displayed on the display, which is highlighted:
• by the presence of two decimal points on the first
two left digits (representing the parameter number)
• of the letter
distinguish them from those of the simplified
version (which are different)
N.B.: The operation can be performed several times,
switching from one mode to another at will.
The table in paragraph 4.6 contains the parameters
for extended mode.
rE S-
A1
in extended mode (

Simplified/extended parameters

mode change

unit
provides
SIMPLIFIED MODE
hold the buttons for 4 s
EXTENDED MODE
A
in parameters less than 10, to
flashing,
C-
in
two
modes