Simplified/Extended Parameters Mode - Roger Technology B70/1DC Instrucciones Y Advertencias Para El Instalador

Ocultar thumbs Ver también para B70/1DC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 84
which indicates that the values have been restored.
5.2.3
Simplified/extended parameters
mode change
The
control
unit
configuration: extended or simplified.
In extended mode the installer can change a lot
of parameters, but you need a more in-depth
knowledge of the product.
Simplified mode has been designed for ease of
installation, only a few parameters can be changed.
It is the recommended mode for an installer who is
not very familiar with the product and who does not
need special configurations.
WARNING!
The product leaves the factory set in simplified
mode, with standard values which satisfy the
STANDARD
PARAMETER
AND VALUE
Position of the motor
0- 01
with respect to the gap
1- 00
Automatic reclosing
2- 30
Pause time
3- 00
Emergency blackout
4- 05
Brake adjustment
5- 00
Pre-flashing
6- 00
Step-by-step mode
7- 00
Flashing configuration
Duration of acceleration
8- 04
phase
9- 05
Speed regulation
Duration of deceleration
a- 04
phas
Impact of force level
b- 15
provides
two
modes
FUNCTION
DISPLAY
01 - 15 number of attempts to reclose (interrupted by
00 - 90 seconds of pause
92 - 99 2 minutes...9 minutes of pause
01 - 10 01 = sudden braking ... 10 = soft braking
01 - 10 pre-flashing seconds
01 - 05 01 = short acceleration period ...
01 - 05 01 = minimum speed .... 05 = maximum speed
01 - 05 01 = short deceleration period ...
01 - 10 low torque motor
11 - 19 medium torque motor
majority of installations.
of
If you want to go to extended mode hold the UP and
DOWN buttons both for 4 seconds, after this time
the first of the parameters of the extended version
VALUE
ON
motor on the LEFT with respect to the gap looking from inside
00
motor on the RIGHT with respect to the gap looking from inside
01
deactivated
00
photocell) before finally staying opened
always tries to reclose, without limitation
99
deactivates the reclosing when power returns
00
enables the reclosing when power returns
01
deactivated
00
5 seconds of pre-flashing only when closing
99
opens stops closes stops opens stops closes ..
00
condominium, refreshes the pause time
01
condominium, closes from completely open
02
opens closes opens closes
03
opens closes stops opens
04
constant (the light flashes)
00
slow flashing while active
01
slow flashing while opening, fast while closing
02
05 = prolonged acceleration period
10 = prolonged deceleration period
1 minimum impact force ... 10 max. impact force
11 minimum impact force ... 19 max. impact force
Maximun torque motor
20
Without anti-crushing protection (obligatory safety edges)
SIMPLIFIED MODE
hold the buttons for 4 s
EXTENDED MODE
DESCRIPTION
27

Publicidad

Tabla de contenido
loading