Honda ER2500CX Manual De Explicaciones página 50

Ocultar thumbs Ver también para ER2500CX:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

d. Remove the sediment cup, and then turn the fuel valve lever to the
ON position and drain the fuel from the fuel tank.
e. After all the fuel has drained into the container, tighten the drain
bolt securely.
f. Reinstall a new O-ring and sediment cup, and tighten the sediment
cup securely.
g. Turn the fuel valve lever to the OFF position.
2.Change the engine oil (see page 36).
3.Remove the spark plug (see page 43).
4.Pour a teaspoon (5 cm
5.Pull the starter grip several times to distribute the oil in the cylinder.
6.Reinstall the spark plug.
7.Slowly pull the starter grip until resistance is felt. At this point, the
piston is coming up on its compression stroke and both the intake
and exhaust valves are closed. Storing the engine in this position will
help to protect it from internal corrosion. Return the starter grip
gently.
3
) of clean engine oil into the cylinder.
STORAGE
O-RING (Replace)
SEDIMENT CUP
47