3.1.3. SETTINGS OF EQUIPMENT AND COMPONENTS. MD-1.
Whenever we connect a remote control to Galaxy 300 equipment for the first time, we must calibrate the
synchronisation of the potentiometers of the control and of the control panel.
7. Connect the RC to connector "P" on the front panel.
8. Place the remote control potentiometers "A and B" at maximum position.
9. Open the RC lid with the aid of a screwdriver.
10. Uncover the regulation "Trimer".
11. With the aid of an appropriate sized screwdriver, adjust the "Trimer" to the maximum current of the
equipment on display "L".
12. Close the control cover and start to work.
This calibration should be carried out according to the maintenance chapter guidelines.
3.2. OPERATIONS SEQUENCE FOR STARTING UP THE EQUIPMENT.
9. Prepare the equipment according to the welding process to be performed. From section 3.3. onwards of
this manual you will find the equipment preparation diagram according to the work you wish to carry out.
10. Connect the plug to the mains.
11. Apply the main switch "S" for start-up.
12. The equipment automatically carries out the "on" check (see chapter 5.1).
13. Determine the desired welding process using selector "J".
14. Connect the remote control if needed (see section 3.1.2.).
15. Adjust the desired welding current using the potentiometer "G".
16. Start the welding operation.