Transport And Installation - gala gar GALAXY 3000 GE MV VRD Manual Técnico De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.

TRANSPORT AND INSTALLATION.

2.1. TRANSPORT AND PACKAGING.
Knocks and sudden movements must be avoided when transporting the equipment. In any case, the
packaging must be protected from water.
HANDLE THE EQUIPMENT CAREFULLY, IT WILL LAST LONGER !
2.2. ELECTRICAL SUPPLY INSTALLATION. LOCATION.
The electrical installation of the equipment making up the system must be carried out by specialised
personnel according to the applicable standards.
This equipment can be located and used outdoors (IP 23 protection class). However, we must make sure
that this is a place dry and ventilated, far enough away from the welding area in order to prevent the dust and
pollution caused by the welding process from getting into the equipment. Never work in the rain. The electrical
parts installed must be protected from any direct humidity.
The distribution panel where the machine has to be connected must have the following elements, at least:
DIFFERENTIAL CIRCUIT BREAKER (ID): The aim of this switch is to protect the personnel from direct or indirect contact
with electrical parts under voltage. Bi-polar or Tri-polar (according to mains supply) with a minimum sensitivity of 300 mA.
The EMI system leakage current admits the placement of a 30 mA differential circuit breaker. The differential circuit
breaker is selected in agreement with the Characteristics plate.
AUTOMATIC CIRCUIT BREAKER (IA): Bi-polar.
supply network indicated on the Characteristics Plate.
The GALAXY 3000 equipment has an electricity supply network adaptation system, so that once it is
connected to the mains, the actual equipment makes an assessment of the power supply voltage and
automatically configures the power system. A LED will light up on the control panel on the front of the
equipment, identifying the power supply network the equipment has been connected to (see Chap. 3 and
Chap. 5).
MAINS 230V – 50/60 Hz.
GALAXY 3000 GE MV VRD
The appliance will be selected in agreement with the power
CIF B- 50 /045285
50.014 ZARAGOZA - SPAIN
TYP: GALAXY 3000 GE MV
REF: 440.00.000
3
12 A / 20.4 V - 300A / 32V
U =10V
S
R
U =90V
0
50/60 Hz
U
3
1
12 A / 20.4 V - 200A / 28 V
U =10V
S
R
U =92V
0
U
50/60 Hz
1
1
IP 23 S
RATED
THREE-PHASE
3 Ph. 400 V
THREE-PHASE
3 Ph. 230 V
SINGLE-PHASE
1 Ph. 230V
UNE-EN 60974-1: 00
X
40%
60%
100%
4 0 º C
I
300A
245 A 200 A
2
U
32 V
30 V
28 V
2
I =31 A
I
=49 A
230V
1 m a x
1 e f f
I
=25 A
I =16 A
400V
1 m a x
1 e f f
UNE-EN 60974-1: 00
X
60%
100%
4 0 º C
I
200 A 155A
2
U
28 V 26.2 V
2
I
=41A
I =32 A
230V
1 m a x
1 e f f
RANGE
360 ÷ 450 V
185 ÷ 255 V
185 ÷ 255 V
EN
Three-phase
power supply.
Single-phase
power supply.
NOMINAL
380 / 400 / 415 V
440 V (450 Vmax.)
208 / 220 / 230 V
240 V (255 Vmax.)
208 / 220 / 230 V
240 V (255 Vmax.)
20

Publicidad

Tabla de contenido
loading

Tabla de contenido