Explosion Relief Panel; Replacing Internal Fuse; Spare Parts; Trouble Shooting - Nederman FlexFilter EX Manual De Instrucciones

Ocultar thumbs Ver también para FlexFilter EX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 129
16.10

Explosion relief panel

The explosion relief panel is designed to rupture and open at very low over
pressures and must be handled with great care. Never poke/press or lean
against the relief panel and do not bend the frame securing the panel.
Inspect the explosion relief panel with the vacuum unit switched off.
Replace it at the first sign of corrosion or other damage. No other preventive
maintenance is required.
WARNING!
Risk of personal injury.
Relief panel must be kept free from debris such as snow, ice, leaves and other
items that might block or prevent explosion panel from opening.
16.11

Replacing internal fuse

WARNING!
Risk of personal injury.
The FlexFilter EX should not be in operation when replacing the fuse.
WARNING!
Risk of personal injury.
Ensure that no explosive atmosphere and/or dust layers are present when
cleaning, servicing or inspecting the FlexFilter EX.
The control box on the TVFD has a fused terminal for the sensors (see picture
no. 19 / 4). Remove the cover (see picture no. 21 / 6). Open the control box
and open the terminal to replace the fuse.
17

Spare parts

See www.nederman.com
State control number according to the type label of the product.
18

Trouble shooting

If the trouble shooting guide do not solve the problem, contact your nearest
authorised dealer or AB Ph. Nederman & Co. for technical advice.
Error
Control filter pressure switch
triggered.
No dust collected in Bulk-Bags /
container.
Possible cause
Control filter blocked
6 mm hoses to pressure switch are
blocked or damaged.
The filter in air hose full.
Pressure switch / filter not connected
properly.
Pressure switch set to low
Pressure switch broken
Control system setting incorrect.
TVFD feed-out not working
Filter cleaning not working.
FlexFilter EX
Solution
Change control filter.
Check main filter for damage.
Clean / replace hose.
Replace filter in air hose.
Check connections.
Increase setting (Pre-set: 4kPa)
Replace
See the instructions for the control
system you use.
See chapter 17. Maintenance
See chapter 17. Maintenance
EN
55