FlexFilter EX
19

Installation protocol

NOTE! The results for the following control points. For values note the value
in the result column, else a tick will suffice if the point has been preformed
or considered. If a value is outside the limit or a result is wrong/ missing this
must be rectified before initial start-up and normal operation.
Correct limits or results can be seen within the parenthesis.
FlexFilter EX No
Control points
Application requirements Limits?
Installation Area classification (22 or none)
Material MIE (>1 mJ)
Material MIT (>205 C)
Material Kst: See the product identification plate.
Material Pmax: See the product identification plate.
Material chemical / thermal reaction risk ( No)
Delivery control
Missing components
Transport damage
Pre installation
Foundation - Traction forces
Foundation - Wind load
Foundation - Total weight
Foundation - Anchor bolts
Flame and pressure risk area
Maintenance access /filter change
Mounting
Legs
Cross beams
TVFD
Cleaning valve
Relief Panel Sensor
Bulk-Bag / container
Duct system
Dimensioning / transport velocity
Pressure resistant inlet (Yes)
Isolation valve (Yes)
Suction source
Electrical Installation
Control voltage
Connections – Connection box
58
Date
Preformed by:
Result