With the UP and DOWN keys it is possible to scroll through the following menus:
Menu for set-point settings
A.
Set-point
Clock/Time
Menu for setting Time and time bands
B.
bands
Menu for setting FDL and FNR option
C.
Restrictions
Menu for viewing the digital/analogue inputs/outputs
D.
Inputs/Outputs
status of the board
Menu for alarm log display
E.
Alarm log
Info Menu
F.
Info
Language
G.
Language setting menu
change
Menu for displaying the compressor operation hour
H.
Work hours
meter
Configuration menu of the BMS ports
I.
Config. BMS
Press ENTER to confirm selection and access the desired menu
I.3.2

Menu Set-point

The set-point menu enables you to set the operation mode to the water's set-point
temperature for each operation mode (cooling, heating, recovery and DHW).
I.3.2.1
Change of operating mode
Sets whether the selection of the unit's operating mode must be made via
1
the display or via external digital contact (Paragraph II.3.2, Summer/winter
selector - SEI)II.3.2
If the selection of the operating mode of the machine occurs via the display
2
you can set:
COOLING and HEATING for HP versions without RC100
AUTOMATIC and SELECT for EXP or HP+RC100 versions
In Automatic mode, the unit automatically selects whether to cool the
primary side and/or heat the recovery side based on heating capacity
request. In Select mode, the unit automatically selects whether to heat the
primary side or recovery side based on heating capacity request
(Only with freecooling versions) It sets the operating mode of the
3
Freecooling (only with FC): CHILLER+FREECOOLING = the unit can
operate with compressors as well as with freecooling (default) / ONLY
FREECOOLING = compressors operation is inhibited / ONLY CHILLER =
freecooling operation is inhibited
Set the adjustment curve of the AF + function
4
Enables ECONOMY parameters for applications with radiant systems
5
I.3.2.2
AF+ function
The AF+ function can be set in Economy or Precision mode.
In Economy mode it is possible to combine comfort with the need for low energy
consumption. In fact, by adjusting the Set-point value, it optimises compressor
operation on the basis of the actual working conditions.
If it is set to PRECISION mode, it is possible to set the set-point compensation in
the following screen via the climatic curve.
Using the Precision function makes it possible to achieve the smallest possible
average fluctuation, at partial loads, from the average Set-point of the water
temperature delivered to the users.
The AF+ function is not available for versions with screw or Turbocor compressor
or if the adjustment is set on the return.
It is possible to choose between the following types of efficiency:
Label
Features of the regulation curve
Use the set-point set by the user (default)
Precision
Buildings with very unbalanced loads
Economy LOW
Efficiency higher than the standard
Intermediate comfort and efficiency (default)
Economy MED
Buildings with well-distributed loads
Economy HIGH
High efficiency
USM_CONTROL EQS_2335a21275_208549_210701_ES-EN-FR-DE-IT
The three adjustment curves correspond to three different laws of variation of the
Set-point based on the load, in order to modify the degree of comfort which can be
obtained in the room and the efficiency of the machine.
x
y
S
LOW
MED
HIGH
1
The following screen enables you to set the unit's work set-point from the display
2
for cooling, heating and recovery mode.
3
It is also possible to change the work set-point by means of the DSP digital
contact (default accessory) or by means of the climatic compensation function.
4
5
The double set-point function allows the use of two different set-points on the
basis of a digital input.
Closing/opening a DSP input decides the set-point to use for all operating modes
(cooling, heating, recovery); to exclude DSP action in an operating mode, set both
set-points with the same value in that operating mode.
For further information, refer to the wiring diagram attached to the machine.
To the car.
The set-point currently used by the unit is identified by an arrow.
Cooling mode settings
1
2
3
4
67
AF+ in Cooling/AUTOMATIC
AF+ in Cooling/SELECT
Load percentage (%)
Set-point (°C)
Set-point entered by user
Buildings with very unbalanced loads
Efficiency higher than the standard
Intermediate comfort and efficiency (default)
Buildings with well-distributed loads
High efficiency
I.3.2.3
Double Set-point (DSP accessory)
Input status
Open contact
ATTENTION
Closed Contact
I.3.2.4
Set-point setting
Main set-point in COOLING/AUTOMATIC mode
Secondary set-point in COOLING/AUTOMATIC mode (only with DSP
option)
Correction applied to set-point with CS function in Offset mode (only with
CS option)
Set-point display of actual work
CONTROL EQS
Set-point in use
Set-point 1
Set-point 2
1
2
3
4