Step 2 Install Water Line - Monogram ZIP360NN Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions- Stainless Steel Installation

STEP 2 INSTALL WATER LINE

WARNING
Connect to potable water supply
only. A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 psi (275-827 kilopascals).
WARNING
ELECTRIC SHOCK HAZARD
Attach tubing clamp using existing hole only. DO NOT
drill into the refrigerator.
AVERTISSEMENT
alimentation d'eau potable seulement. Une alimentation
d'eau froide est requise pour faire fonctionner
la machine à glaçons et le pichet à remplissage
automatique. La pression d'eau doit se situer entre 40
et 120 psi. (275 à 827 kPa).
AVERTISSEMENT
Fixez le collier de serrage dans le trou présent seulement.
NE PERCEZ PAS dans le réfrigérateur.
ADVERTENCIA
Realice la conexión a un
suministro de agua potable únicamente. Se requiere
un suministro de agua fría para el funcionamiento de la
máquina de hielos automática y de la jarra de llenado
automático. La presión del agua deberá estar entre 40
y 120 p.s.i. (275 – 827 kPa).
ADVERTENCIA
Adhiera la abrazadera de la tubería usando el agujero
existente únicamente. NO perfore el refrigerador.
• A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 p.s.i. (275-827 kPa).
• Route 1/4" OD copper or SmartConnect
tubing between house cold water line and the water
connection location.
• Tubing should be long enough to extend to the front of
the refrigerator. Allow enough tubing to accommodate
bend leading into the water line connection.
Raccordez l'appareil à une
RISQUE DE DÉCHARGE
ÉLECTRIQUE
PELIGRO DE DESCARGA
ELÉCTRICA
plastic
Floor
Waterline Tubing
STEP 2 INSTALL WATER LINE
(Cont.)
NOTE: The only Monogram Appliances-approved
plastic tubing is supplied in the SmartConnect
Refrigerator Tubing kits. Do not use any other plastic
water supply line because the line is under pressure at
all times. Other types of plastic may crack or rupture
with age and cause water damage to your home.
SmartConnect
Refrigerator Tubing Kits are available in
the following lengths:
2' (.6 m)
WX08X10002
8' (2.4 m)
WX08X10006
15' (4.6 m) WX08X1 0015
25' (7.6 m) WX08X10025
Shut off the main water supply.
Turn on the nearest faucet long enough to clear the line
of water.
• Install a shut-off valve between the icemaker water
valve and cold water pipe in a basement or cabinet.
The shut-off valve should be located where it will be
easily accessible.
• Turn on the main water supply and flush debris.
Run about a quart of water through the tubing into a
bucket. Shut off water supply at the shut-off valve.
NOTE: Saddle type shut-off valves are included in
many water supply kits, but are not recommended for
this application.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
32
31-1000451 Rev. 0

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zips360nnss

Tabla de contenido