Table 1-5 Specifications for GF100/GF120/GF125 Series with EtherCAT Communications
Performance
Performance
Performance
Performance
Performance
Full Scale Flow Range
Full Scale Flow Range
Full Scale Flow Range
Full Scale Flow Range
Full Scale Flow Range
Flow Accuracy
Flow Accuracy
Flow Accuracy
Flow Accuracy
Flow Accuracy
Repeatability & Reproducibility
Repeatability & Reproducibility
Repeatability & Reproducibility
Repeatability & Reproducibility
Repeatability & Reproducibility
Flow Settling Time (NC Valve)
Flow Settling Time (NC Valve)
Flow Settling Time (NC Valve)
Flow Settling Time (NC Valve)
Flow Settling Time (NC Valve)
Flow Settling Time (NO Valve)
Flow Settling Time (NO Valve)
Flow Settling Time (NO Valve)
Flow Settling Time (NO Valve)
Flow Settling Time (NO Valve)
Pressure Insensitivity
Pressure Insensitivity
Pressure Insensitivity
Pressure Insensitivity
Pressure Insensitivity
Control Range
Control Range
Control Range
Control Range
Control Range
MultiFlo
MultiFlo
MultiFlo
MultiFlo
MultiFlo
#of Bins
#of Bins
#of Bins
#of Bins
#of Bins
Valve Shut Down (N.C. Valve)
Valve Shut Down (N.C. Valve)
Valve Shut Down (N.C. Valve)
Valve Shut Down (N.C. Valve)
Valve Shut Down (N.C. Valve)
Valve Shut Down (N.O. Valve)
Valve Shut Down (N.O. Valve)
Valve Shut Down (N.O. Valve)
Valve Shut Down (N.O. Valve)
Valve Shut Down (N.O. Valve)
Zero Stability
Zero Stability
Zero Stability
Zero Stability
Zero Stability
Temperature Coefficient
Temperature Coefficient
Temperature Coefficient
Temperature Coefficient
Temperature Coefficient
Ratings
Ratings
Ratings
Ratings
Ratings
Operating Temperature Range
Operating Temperature Range
Operating Temperature Range
Operating Temperature Range
Operating Temperature Range
Differential Pressure Range*
Differential Pressure Range*
Differential Pressure Range*
Differential Pressure Range*
Differential Pressure Range*
Maximum Operating Pressure
Maximum Operating Pressure
Maximum Operating Pressure
Maximum Operating Pressure
Maximum Operating Pressure
Leak Integrity (external)
Leak Integrity (external)
Leak Integrity (external)
Leak Integrity (external)
Leak Integrity (external)
Mechanical
Mechanical
Mechanical
Mechanical
Mechanical
Valve Type
Valve Type
Valve Type
Valve Type
Valve Type
Wetted Materials
Wetted Materials
Wetted Materials
Wetted Materials
Wetted Materials
Surface Finish
Surface Finish
Surface Finish
Surface Finish
Surface Finish
Diagnostics & Display
Diagnostics & Display
Diagnostics & Display
Diagnostics & Display
Diagnostics & Display
Status Lights
Status Lights
Status Lights
Status Lights
Status Lights
Alarms
Alarms
Alarms
Alarms
Alarms
Display Type
Display Type
Display Type
Display Type
Display Type
V V V V V iewing Angle / Viewing Distance
iewing Angle / Viewing Distance
iewing Angle / Viewing Distance
iewing Angle / Viewing Distance
iewing Angle / Viewing Distance
U U U U U nits Displayed / Resolution
nits Displayed / Resolution
nits Displayed / Resolution
nits Displayed / Resolution
nits Displayed / Resolution
Electrical
Electrical
Electrical
Electrical
Electrical
Electrical Connection
Electrical Connection
Electrical Connection
Electrical Connection
Electrical Connection
Digital Communication
Digital Communication
Digital Communication
Digital Communication
Digital Communication
Diagnostic /Service Port
Diagnostic /Service Port
Diagnostic /Service Port
Diagnostic /Service Port
Diagnostic /Service Port
Power Supply/Consumption
Power Supply/Consumption
Power Supply/Consumption
Power Supply/Consumption
Power Supply/Consumption
Compliance
Compliance
Compliance
Compliance
Compliance
EMC
EMC
EMC
EMC
EMC
Environmental Compliance
Environmental Compliance
Environmental Compliance
Environmental Compliance
Environmental Compliance
*Argon gas applications require an additional 10 psid differential pressure. Low vapor pressure gases require an inlet pressure of > 100 Torr, with vacuum on
outlet (example SiCl4). Contact Brooks Technical Support for more information.
GF100
GF100
GF100
GF100
GF100
GF120
GF120
GF120
GF120
GF120
3 sccm to 55 slm
+1% S.P. > 20-100%; +0.2% F.S. 2-20%
< 1 sec
700ms
<1.5 sec
Not Applicable
2-100% (Normally Closed Valve)
3-100% (Normally Open Valve)
Standard
11 bins
0.15% of F.S.
2% of F.S.
< + 0.15% F.S. per year
Zero: 0.005% F.S. per
3-860 sccm = 7-45 psid
861- 7200 sccm = 10-45 psid
7201-55000 sccm = 15-45 psid
500 psia max
Normally Closed
Normally Open
Meter (no valve)
SEMI F20 HP Compliant, 316L VIM/VAR, Hastelloy C-22, 316L Stainless Steel, 304 Stainless Steel, KM-45
10μ inch Ra
Control Valve Output, Network Interruption, Temperature High/Low, Pressure High/Low, Power Surge/Sag
320 mA max. @ 18-30 Vdc, 230 mA max. @ 24 Vdc (under typical operating conditions)
EMC Directive 2014/30/EU Evaluation Standard EN61326-1:2013
RoHS Directive (2011/65/EU)
REACH Directive EC (1907/2006)
GF125
GF125
GF125
GF125
GF125
< + 0.15% S.P.
300ms (3-860 sccm N2 Eq.)
400ms (861-7200 sccm N2 Eq.)
500ms (7201-30000 sccm N2 Eq.)
<700ms (30001-55000 sccm N2 Eq.)
< 1% S.P. up to 5 psi/sec
upstream press. spike
o
C
10-50
o
C
100 psia max
1x10^
-10
atm. cc/sec He
5μ inch Ra
Run, Error, Power, Network Status
Top Mount Integrated LCD
Rotatable / 10 feet
Flow (%), Temp. (
o
C), Pressure (psia, kPa) / 0.1 (unit)
Power via 5-pin M8 Connector, EtherCAT via RJ45 jacks
EtherCAT
Micro-USB
Section 1 Introduction
GF100 Series
GF120XSL
GF120XSL
GF120XSL
GF120XSL
GF120XSL
GF120XSD
GF120XSD
GF120XSD
GF120XSD
GF120XSD
4 sccm to 25 sccm
>25 sccm to 1 slpm
±1% S.P. 35-100%; ±0.35% F.S. 2-35%
< 3 sec
----------
----------
2-100% (Normally Closed Valve)
----------
----------
<1% of F.S.
----------
< + 0.6% F.S. per year
Zero 0.005% of F.S. per °C
10 Torr - 30 psid typical
For more details
consult factory
up to 500 psia max
Normally Closed
5μ inch Ra
1-11