Section 1 Introduction
GF100 Series
Table 1-6 Specifications for GF135 Series
P P P P P erformance
erformance
erformance
erformance
erformance
Full Scale Flow Range:
Full Scale Flow Range:
Full Scale Flow Range:
Full Scale Flow Range:
Full Scale Flow Range:
Gasses Supported:
Gasses Supported:
Gasses Supported:
Gasses Supported:
Gasses Supported:
Flow
Flow Accur
Flow
Accur
Accuracy:
Accur
acy:
acy:
acy:
Flow
Flow
Accur
acy:
Repeatability & Repr
Repeatability & Repr
oducibility:
oducibility:
Repeatability & Reproducibility:
Repeatability & Repr
Repeatability & Repr
oducibility:
oducibility:
Linearity:
Linearity:
Linearity:
Linearity:
Linearity:
Settling Time (to within +/-2% FS):
Settling
Settling
Settling
Settling
Time (to within +/-2% FS):
Time (to within +/-2% FS):
Time (to within +/-2% FS):
Time (to within +/-2% FS):
Pr Pr Pr Pr Pressur
essur
essur
e Insensitivity:
e Insensitivity:
essure Insensitivity:
essur
e Insensitivity:
e Insensitivity:
Contr tr tr tr trol Range:
Con
Con
Con
Con
ol Range:
ol Range:
ol Range:
ol Range:
V V V V V alve Shut Down:
alve Shut Down:
alve Shut Down:
alve Shut Down:
alve Shut Down:
Z Z Z Z Z er er er er ero Stability:
o Stability:
o Stability:
o Stability:
o Stability:
T T T T T emper
emper
emper
atur
atur
e Coefficien
e Coefficient: t: t: t: t:
e Coefficien
emper
emperatur
atur
ature Coefficien
e Coefficien
Rate-of-Decay P
Rate-of-Decay P
Rate-of-Decay Performance:
Rate-of-Decay P
Rate-of-Decay P
erformance:
erformance:
erformance:
erformance:
Flow Rate:
Flow Rate:
Flow Rate:
Flow Rate:
Flow Rate:
T T T T T emper
emperatur
emper
emper
atur
atur
ature Sensitivity:
e Sensitivity:
e Sensitivity:
e Sensitivity:
emper
atur
e Sensitivity:
Pr Pr Pr Pr Pressur
essur
essur
e Sensitivity:
e Sensitivity:
essure Sensitivity:
essur
e Sensitivity:
e Sensitivity:
Minimum Detectable Change
Minimum Detectable Change
Minimum Detectable Change
Minimum Detectable Change
Minimum Detectable Change
fr fr fr fr from Commissioning Baseline:
om Commissioning Baseline:
om Commissioning Baseline:
om Commissioning Baseline:
om Commissioning Baseline:
Ratings
Ratings
Ratings
Ratings
Ratings
Oper
Oper
ating
ating
ating T T T T T emper
emper
emper
atur
atur
e Range:
e Range:
Oper
Operating
Oper
ating
emperatur
emper
ature Range:
atur
e Range:
e Range:
Differ
Differ
Differ
Differen en en en ential Pr
Differ
tial Pr
tial Pressur
tial Pr
tial Pr
essur
essur
essure Range**:
essur
e Range**:
e Range**:
e Range**:
e Range**:
Maximum Oper
Maximum Operating Pr
Maximum Oper
Maximum Oper
Maximum Oper
ating Pr
ating Pr
ating Pr
ating Pressur
Pneumatic
Pneumatic
Pneumatic
Pneumatic
Pneumatic V V V V V alve Oper
alve Operating Pr
alve Oper
alve Oper
alve Oper
ating Pr
ating Pr
ating Pr
ating Pressur
Leak In
Leak In
Leak Integrity (external):
tegrity (external):
tegrity (external):
tegrity (external):
Leak In
Leak In
tegrity (external):
Mec
Mec
Mechanical
Mec
Mec
hanical
hanical
hanical
hanical
V V V V V alve
alve T T T T T ype:
alve
alve
ype:
ype:
alve
ype:
ype:
W W W W W etted Materials:
etted Materials:
etted Materials:
etted Materials:
etted Materials:
Surface Finish:
Surface Finish:
Surface Finish:
Surface Finish:
Surface Finish:
Diagnostics & Display
Diagnostics & Display
Diagnostics & Display
Diagnostics & Display
Diagnostics & Display
Status Lights:
Status Lights:
Status Lights:
Status Lights:
Status Lights:
Alarms:
Alarms:
Alarms:
Alarms:
Alarms:
Display T T T T T ype:
Display
Display
Display
Display
ype:
ype:
ype:
ype:
Viewing Distance:
Viewing Distance:
Viewing Distance:
Viewing Distance:
Viewing Distance:
Units Displayed / Resolution:
Units Displayed / Resolution:
Units Displayed / Resolution:
Units Displayed / Resolution:
Units Displayed / Resolution:
Electrical
Electrical
Electrical
Electrical
Electrical
Electrical Connection:
Electrical Connection:
Electrical Connection:
Electrical Connection:
Electrical Connection:
Digital Communication:
Digital Communication:
Digital Communication:
Digital Communication:
Digital Communication:
Diagnostic / Service P
Diagnostic / Service P
ort:
ort:
Diagnostic / Service Port:
Diagnostic / Service P
Diagnostic / Service P
ort:
ort:
P P P P P ower Supply/Consumption:
ower Supply/Consumption:
ower Supply/Consumption:
ower Supply/Consumption:
ower Supply/Consumption:
Compliance
Compliance
Compliance
Compliance
Compliance
EMC
EMC
EMC
EMC
EMC
En En En En Envir
vir vir
vir vironmen
onmen
onmen
onmen
onmental Compliance
tal Compliance
tal Compliance
tal Compliance
tal Compliance
1-12
3 sccm to 5 slm (N2 Eq.)
N2, O2, Ar, H2, SF6, NH3, CO2, Cl2, HBr, NF3, CF4, CH4, CH3F, CH2F2, SiCl4 (@ 100 Torr),
C4F6-q (@ 800 Torr), C4F8 (@ 1200 Torr), N2O, CHF3, SiH2Cl2, C5F8, He
+/-1.0% S.P. (10-100% F.S.), +/-1% S.P. plus +/-0.04% F.S. (2-10% F.S.)
< +/- 0.15% S.P.
Included in accuracy
<300ms (<860 sccm N2 Equivalent), <400ms (861-5000 sccm N2 Equivalent)
< 1% S.P. up to 5 psi/sec upstream press. spike
1-100%
< 0.5% of F.S. N2
< +/- 0.5% F.S. per year
Span: 0.05% setpoint per °C, Zero: 0.005% F.S. per °C
(ROD by default is disabled/off. It should not be enabled until after MFC is installed and properly commissioned)
Maximum flow rate for which an ROD measurement can be obtained is 800 sccm
+/- 0.04% S.P./Deg C
+/- 0.04% F.S./psi
Zero Drift: +/- 0.02% F.S.
Valve Leak: +0.1% F.S.
Repeatability: +/- 0.3% S.P. (SiCl4 +/- 0.5% from 5-100% S.P. up to 100 sccm flow)
10-50°C
3-860 sccm = 7-45 psid, 861- 5000 sccm = 10-45 psid
**Typical pressure drop. Actual pressure drop will be gas and flow dependent.
Argon gas applications require higher differential pressure.
Low vapor pressure gases require an inlet pressure of > 100 Torr, with vacuum on outlet
(example SiCl4). Contact Brooks Technical Support for more information.
essur
essure: e: e: e: e:
essur
essur
100 psia max
essure: e: e: e: e:
essur
essur
essur
43.5 psia - 72.5 psia
1x10-10 atm. cc/sec He
Normally Closed
SEMI F20 UHP Compliant 316L VIM/VAR, Hastelloy C-22,316L Stainless Steel, 304 Stainless Steel, KM-45
4μ inch Ra (0.1 μm Ra)
MFC Health, Network Status
Sensor Output, Control Valve Output, Over Temperature, Power Surge/Sag, Network Interruption,
Sensor Drift, Flow Error, Valve Leak
Top Mount Electronically Rotatable Integrated LCD
Fixed / 10 feet
Flow (%), Temp. (°C), Pressure (psia, kPa) / 0.1 (unit)
Analog/RS-485 via 9-Pin "D" connector, DeviceNet via 5-Pin "M12" connector
RS485+ (model specific), DeviceNet (model specific), RS485 Diagnostic Port (all models)
RS485 via 2.5 mm jack
DeviceNet: +11-25 Vdc., 545 mA max. @ 11 Vdc., 250 mA (max.) @ 24 Vdc.,
Analog /RS485: +/-15 Vdc. (+10%), 6 Watts (max) or +24 Vdc +/-10%
EC Directive 2004/108/EC CE: EN61326: 2006 (FCC Part 15 & Canada IC-subset of CE testing)
RoHS Directive 2011/65/2006
Reach Directive EC 1907/2006
Installation and Operation Manual
X-TMF-GF100-Series-MFC-eng
Part Number: 541B137AAG
April, 2017

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gf125 analog i/oGf125 digital i/oGf135 analog i/oGf121 analog i/o

Tabla de contenido