Troubleshooting - GYS DIAG-STARTIUM 60-12 Manual Del Usuario

Ocultar thumbs Ver también para DIAG-STARTIUM 60-12:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
WARNING
• WARNING! Explosive gas , avoid lames and sparks . During charging, the battery should be placed in a ventilated
area.
• Protect the unit from rain and moisture
• If the power cable is damaged it must be replaced by the manufacturer , its after sales department or a similarly
qualiied person to avoid hazard.
• The external fuse can be replaced and the circuit breaker can be engaged by the user.
• Under no circumstances should this appliance should be used to charge accumulators or non rechargeable batteries.
• Respect the connection sequence indicated .
• Product subject to separate collection , do not dispose in domestic waste .
• This appliance is not intended for use by persons (including children) with reduced physical , sensory or mental
capabilities, or lack of experience or knowledge, unless they are supported by a person responsible for their safety,
supervision or instruction concerning use of the appliance .
• Do not open the device. Modiications not performed by the manufacturer's technician will void the warranty .
• Check that the available input voltage corresponds to the one indicated on the nameplate of the charger.

TROUBLESHOOTING

Troubleshooting
Error LED lashes
Error LED lashes and alarm beep
The LEDs won't light up
In START ENGINE mode, if the screen
displays 0%. Restart impossible.
Battery is boiling.
12
DIAG-STARTIUM 60-12 / 60-24
Causes
Power supply issue.
Clamps in short-circuit or polarity
reversal.
The battery is faulty.
Voltage error (6V-12V-24V)
Battery not detected or <1V. Display :
«BAt HS»
After intensive use the device goes to
thermal protection. Display : «th»
Power supply issue.
The internal fuse is melt.
The ON/OFF switch is not engaged.
The battery is sulphated, start
is avoided to protect the vehicle
electronics.
The voltage selected 12 or 24V is not
correct.
The battery has element in short-
circuit.
Remedies
Check the power supply.
Check if the fuses have blown.
Do not put the clamps in short-circuit.
Reverse the polarity.
Check the voltage at the battery
terminals with a voltmeter. If the
voltage instantaneously increase
by more than 2.5V by element the
battery can be sulphated or damaged.
Check if the battery is correctly
connected either in 6V, 12V or 24V.
Connect the battery.
Select TIMER if the battery voltage is
<1V.
Wait 1/4h for the device to cool
down.
Check the power supply.
Send the device back to GYS after
sales.
Switch the ON/OFF button.
Recharge the battery prior using
START ENGINE.
Check the battery voltage and
connect it following the recommended
connection.
The battery cannot be recovered, it
must be replaced.
EN