8 Putting out of operation

NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Consult the documentation for the welding components.
 6 Putting into operation on page EN-11
 Fig. 4 Control elements/ports on page EN-14
1 Set the rotary power switch (4) on the extraction system to the ON position.
2 Set the switch to manual/automatic (3).
7.1 Control elements/ports
1
Service LED
2
Power LED
Fig. 4
Control elements/ports
7.1.1 Statuses of the service LED
The service LED is illuminated in the following three scenarios:
1 Phases are reversed.
Service LED 1sec. on, 1sec. off.
2 Compressed air is not connected.
Service LED 2 sec. on, 2sec. off.
3 Filter is worn.
Service LED is continuously illuminated.
8 Putting out of operation
 Fig. 4 Control elements/ports on page EN-14
1 Set the rotary power switch (4) on the extraction system to the OFF position.
2 Disconnect the extraction system from the power supply.
3 If necessary, disconnect the compressed air supply and earth cable.
EN - 14
1
2
3
6
3
Auto/manual switch
4
On/Off rotary power switch
xFUME VAC PRO
4
5
5
Power cable port
6
Control lead port
BAL.0732.0 • 2019-09-18