7

Commissioning

8017854.16K9 | SICK
Subject to change without notice
Table 11: Q1 output ACTIVE states for Dark Switching variants with Alarm/Health and adjustable
time delay
HSE18-Xxxxx_
HSE18-Yxxxx_
HSE18-Jxxxx_
HSE18-Kxxxx_
No Time Delay
Q1 = D.ON
-xxxxxC
-xxxxxF
Q1 = D.ON
-xxxxxI
1
Adjustabl
-xxxxxM
e ON
Delay
-xxxxxI
Q1 = L.ON
2
-xxxxxD
-xxxxxG
Q1 = D.ON
-xxxxxK
1
Adjustabl
-xxxxxN
e OFF
Delay
-xxxxxK
Q1 = L.ON
2
1
L/D Selection Switch in in the "D" Dark Switching position
2
L/D Selection Switch in in the "L" Light Switching position
1
Alignment
100 %
0 %
Figure 5: Signal strength light bar during alignment
Red light: Align the sender with the receiver. Select the position so that the red emitted
light beam hits the receiver. Tip: The signal strength light bar on the rear of the sensor will
help to ensure correct alignment. Use white paper or a reflector as an alignment aid. The
sender must have a clear view of the receiver, with no object in the path of the beam [see
figure
6]. You must ensure that the optical openings (front screen) of the sensors are com‐
pletely clear.
100 %
100 %
0 %
0 %
7
COMMISSIONING