Setting The Modes - SICK LCU-P Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 127
Operating instructions
LCU-P
8 008 364/NB 86/25-04-00 © SICK AG • Safety Systems • Germany • All rights reserved
General
3.3

Setting the modes

All set up LCU operating modes can be called up using a
corresponding BCD switch. A bridge connection or direct
selection using the "run modes" program is possible for a fixed
operating mode. Standard operating modes, such as guard
only, single-break, double-break are provided preprogrammed,
i.e. the interface can be operated without user programming.
Safety-related settings such as "with contactor monitoring" or
"break time out 28 s" are installed on site.
Furthermore, 3 positions of the selector switch can be assigned
to user-definable application programs (fig. 2).
input
1
2
0
0
0
0
0
1
1
0
1
1
1
0
0
1
(1
1
0
Input not connected with (48) (open)
1
Input connected with (48)
Fig. 2: Connection terminals for operating mode selector
switch, with assignment
External
Mode Select
1
2
3
48
49
50
51
3
0
keyboard mode (programming)
1
guard only operation
0
single-break
0
double-break
0
user program 1
1
user program 2
1
user program 3
1
not used)
GB
Chapter 3
323

Publicidad

Tabla de contenido
loading

Tabla de contenido