7

COMMISSIONING

-Nx1xx
-Nx2xx
-Nx3xx
-Nx4xx
D.ON, NPN Open Collector Q (≤ 100 mA)
7
Commissioning
7.1

Alignment

7.2

Sensing range

8
Align the sensor with a suitable reflector. Select the position so that the red emitted
light beam hits the center of the reflector. The sensor must have a clear view of the
reflector, with no object in the path of the beam [see
optical openings of the sensor and reflector are completely clear.
Figure 1: Alignment
Adjust the distance between the sensor and the reflector according to the correspond‐
ing diagram [see
figure
2] (x = sensing range, y = operating reserve).
After alignment is complete, move a non-transparent object into the path of the beam.
Use
table 2
to check the function. If the switching output fails to behave in accordance
with
table
2, check the application conditions.