Fig. 5b
Add 3 ft (0.9m) of
fall clear- ance to
calculation if user
may be working in a
crouched or kneeling
position.
Fig. 5d
Worker must not be
exposed to a swing
fall hazard.
7- INSPECTION AND MAINTENANCE
7-1 INSPECTION AND OPERATION TESTING
Honeywell Safety Products' inspection requirements incorporate the criteria
established by current safety standards. The inspection criteria for the equipment
shall be set by the user's organization, such that it equals or exceeds the criteria
required by the manufacturer and the standards with which the organization
elects to comply.
Before using the DuraSeal™ for the first time:
- complete the identification sheet by copying the marking information
- complete the inspection label on the product (date of first use + 1 year)
It is your responsibility to make sure that this document is updated and archived. If
nothing is written on the identification file, the product must be considered as not
having been maintained and no guarantee will be given by the manufacturer.
20
Fig. 5c
Whenever a worker may not be
working directly under the anchor
point or may be moving back
and forth from the vertical of the
unit, the swing fall factor must
be included in the fall clearance
calculation. Fall clearance
distance will increase according
to the specifics of the swing fall
conditions. Honeywell Technical
Service can help you
calculate the added fall clearance
required...
If there is any question
about calculating fall clearance distance,
please contact Honeywell Technical
Services:
00 800 33 44 28 03
IS.PPE.TECHSUPPORT.EUROPE@honeywell.com