Bosch Rexroth BT356 Manual De Instrucciones página 34

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
34/124
Bosch Rexroth AG
Table 5 shows an overview of the power
consumption of tightening spindles and
ErgoSpin hand-held nutrunners.
Table 5: Tightening channel power consumption
Servo
Tightening
amplifier
spindle
LT355
Size 5
LT354
Size 4
LT353
Size 3
Size 2
Servo
ErgoSpin
amplifier
hand-held
nutrunner
LTU350/1
ESA220S
ESA150S
ESA100S
ESV146
ESV073
ESA075...
ESA065...
ESA056...
ESA040...
ESV050
ESV025
ESM025
ESM035
ESA030...
ESA013...
ESA005...
ESV012
ESV005
ESM012...
Control cabinet air conditioning/
resulting power loss
The resulting losses in the control cabinet
are, on the one hand, dependent on the
installed modules in the BT356 (static power
loss) and, on the other, on the tightening case
Power
consumption
(variable power loss). The calculation for
expected losses is as described below.
45 A
28 A
Table 6: Losses in installed components
14 A
Module
7 A
Power
consumption
Per card rack (BT356 + VM350)
Per channel (SE352(M), LT35x,
EC30x, xMCyyy)
50 A
Per channel (SE352(M), LTU350/1,
ErgoSpin)
Per KE350(G IL)
Per IMxxx
33 A
Per NK350(S)
Table 7:
Characteristic values for calculating the
variable power loss
P
18 A
1
P
11 A
2
M
1
M
2
n
1
n
2
BT356 | 3 609 929 B68/2008-11
Characteristic values depending on each
tightening case (variable values)
Power when screwing in
Max. power during end tightening
Torque when screwing in
Max. torque during end tightening
Tightening speed
End tightening speed
Static
power
loss
48 W
27 W
27 W
5 W
2 W
2 W

Publicidad

Tabla de contenido
loading

Tabla de contenido