Bosch Rexroth AG
Inserting the modules
Insert the individual modules (SE352(M),
KE350(G IL), LTU350/1, LT35x, NK350(S))
into the BT356 as shown in Fig. 7.
SE LT
LT
*Tightening channel: SE352(M) tightening controller
+
LT35x/LTU350/1 servo amplifier
Fig. 7: BT356 slots for individual modules
The slots 1- 6 in the card racks can be
equipped with a tightening channel (LT35x,
LTU350/1, SE352(M)). The KE350(G IL)
must be inserted in the KE slot (on the right of
the card rack). If several card racks are
networked via an NK350(S) network coupler,
the KE350(G IL) must be inserted in the card
rack, which also contains the NK350S
network coupler.
A maximum of one KE350(G IL) and 40
tightening channels can be operated in one
tightening system.
The outer right slot is only intended for the
NK350(S) network coupler.
Tightening
channel*
Slide the individual modules along the upper
Tightening
and lower guides.
channel*
Tightening
The modules should be completely inserted
channel* or
KE350(G IL)
into the BT356 and secured with the knurled
bolts.
For safety reasons and EMC regulations,
close off unoccupied slots using dummy
panels.
Mains connection and power loss
NK350(S)
Tightening
channel*
Tightening
channel*
Tightening
channel*
VM350
BT356 | 3 609 929 B68/2008-11
CAUTION
Risk of damage to persons
and property!
The card rack may only be
operated in grounded networks. It
is not permitted to operate the
card rack in networks that are not
directly grounded (IT network), as
air paths and creepage distances
in the module may be
overloaded.Operation in
asymmetrical networks (one
phase is grounded) is not
permitted!