Select Pipe Class
1. Press the <Right Arrow> to select [Pick Pipe Class]. Press <Right Arrow> again and
2. Press <ENTER> to select.
3. Pre-programmed Pipe Size and relevant pipe parameters will appear in menu cells. Press
4. Press the <Left Arrow> and return to the main menu.
Select Liquid Class
1. Press the <Down Arrow> and scroll to [Application Data].
2. Press the <Right Arrow> to select [Liquid Class].
3. Press the <Right Arrow> again and scroll to desired liquid.
4. Press <ENTER> to save selection.
FUS1010 IP65 NEMA 4X & IP66 NEMA 7 Quick Start
Operating Instructions, 01/2013, A5E03086486-AC
scroll to desired Pipe Class.
<Right Arrow> and scroll to desired pipe size. Press <ENTER>. Enter dimensions
manually if pre-programmed dimensions do not match application.
Note
The DN sizes listed in the [Select Pipe Size] menu option list are referenced to DIN Table
2448. After selecting pipe size, check pipe OD and wall thickness for correct dimensions.
Select from list.
Connecting
3.4 Programming the Transmitter
33