Siemens SITRANS F FUS1010 IP65 NEMA 4X Instrucciones De Servicio página 75

Caudalímetros ultrasónico
Ocultar thumbs Ver también para SITRANS F FUS1010 IP65 NEMA 4X:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Input
● Flow Range: ± 12 m/s (± 40 ft/s), bidirectional
● Flow sensitivity: 0.0003 m/s (0.001 ft/s), flow rate independent
Accuracy
● Calibratable accuracy: ± 0.15% to 0.3% of flow, depending on version
● Batch repeatability: ± 0.05% of flow, maximum
● Zero Drift: 0.0003 m/s (0.001 ft/s), with ZeroMatic path active
● Data refresh rate; 5 Hz (80 Hz output for flow rate available on special order)
Power Supply
● IP65 (NEMA 4X) and IP66 (NEMA 7) Wall Mount - 90 to 240 VAC @ 50 or 60 Hz 30 VA /
Sensor
● Type: Nonintrusive, externally mounted
● Temperature Range: -40°C to +120°C (-40°F to +250°F)
Dimensions
● 23.6 cm (9.31 in) x 28.7 cm (11.31 in)
● Net weight: 4.1 kg (9.0 lbs.) max
Liquid Temperature
● Standard: -40°C to +121°C (-40°F to +250°F)
● Optional: -40°C to +232°C (-40°F to +450°F)
Liquid Type
● Water
● Multiple Crude Oils
● Light Crude only
● Heavy Crude only
● Multiple Finished Products
● Gasolines Only
● Kerosene
● Jet Fuel
FUS1010 IP65 NEMA 4X & IP66 NEMA 7 Quick Start
Operating Instructions, 01/2013, A5E03086486-AC
9 to 36 VDC, 12 Watts
Appendix
A.2 Technical Data
73