6.2 Setup menu

All settings are preset except for the start level. The start level
depends on the inlet height and must be set during the startup
phase. See section
8.4 Setting of LC
adjustments are required, settings can be made via the setup
menu. To open the setup menu, mark the symbol
button
and press the button
means of the buttons
and
pressing the button
. Enter values or select settings from a list
by means of the buttons
and
the button
. See also fig. 15.
The following settings can be made:
start level
rated current
stop delay
start delay
alarm delay
time for maintenance
alarm reset (manually or automatically)
reset to factory settings.
Setup menu
Fig. 15 Menu structure for setup menu
16
221. However, in case
using the
. Navigate through the menu by
. Select the desired menu item by
. Save the settings by pressing
L_01 Start level [mm]
I_02 Rated current [A]
T_01 Stop delay [sec.]
T_02 Start delay [sec.]
T_03 Alarm delay [sec.]
M_01 Maintenance interval [month]
A_01 Reset alarm
G_01 Reset to factory settings
EXIT Back to main menu
180
250
315
3.8
2
0
5
0, 3, 6, 12
Manual/
Automatic
EXIT