Mounting
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood.
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.
The hood is designed to be installed in a corner of the kitchen.
In the case of the presence of panels and/or walls and/or
lateral wall units check that there is sufficient space to install
the hood and that it is always possible to access the
removable parts from the lower side.
Operation
The hood is fitted with a control panel with aspiration speed
selection control and a light switch to control cooking area
lights.
T1. Button ON/OFF lights (Led L1 lit)
T2. Button OFF – Selection button suction speed (power)
1 (Led L2 lit)
T3. Selection button suction speed (power) 2 (Led L2+L3
lit)
T4. Selection button suction speed (power) 3 (Led
L2+L3+L4 liti)
T5. Selection button intensive suction speed (power)
(Led L2+L3+L4 lit + Led L5 flashing) - duration 5 minutes
– after which the hood automatically sets suction speed
(power) 2.
Delayed switch-off of the hood (flashing LEDs):
It is possible to set the delayed hood switch-off by pressing
again for more than 2 seconds the button of the suction speed
(power) active at that time.
The available delayed switch-off options are:
Suction speed (power) 1: 20 minutes
Suction speed (power) 2: 15 minutes
Suction speed (power) 3: 10 minutes
Intensive suction speed (power): 5 minutes
Filter saturation indicator
The hood is equipped with a function that warns the user, at
regular time intervals, when the filters are saturated and it is
necessary to perform their maintenance.
Grease filter saturation indicator: With the hood off (OFF)
all suction speed (power) LEDs light up with steady light for 40
seconds.
Activated charcoal filter saturation indicator: With the
hood off (OFF) all suction speed (power) LEDsflash for 40
seconds.
Activation of the active charcoal filter saturation
signal: normally, this function is disabled; to activate it,
switch off the hood (OFF) and simultaneously press
buttons T3 and T5 for more than 3 seconds. LEDs L3
and L5 will start flashing.
To disable repeat the operation: LEDs L3 and L5 light up
with steady light.
Resetting the filters' saturation indicator:
With the hood on (ON) press button T2 for more than 2
seconds; all LEDs will light up briefly.
Note: if necessary, repeat the operation in case both
indicators (grease filter and activated charcoal filter) are
active.
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Prf0116707a

Tabla de contenido