Setting - SICK WTB4FT DoubleLine Instrucciones De Uso

Ocultar thumbs Ver también para WTB4FT DoubleLine:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 71
6
COMMISSIONING
6.3

Setting

10
Dimensions in mm (inch)
6
(0.24)
4
(0.16)
2
(0.08)
0
–2
(–0.08)
–4
(–0.16)
–6
(–0.24)
0
40
80
120
160
200
240
(1.57)
(3.15)
(4.72)
(6.30)
(7.87)
(9.45)
Distance in mm (inch)
Recommended sensing range for
the best performance
Figure 6: Horizontal light spot size
A
Sensing range min. in mm
B
Sensing range max. in mm
C
Viewing range
D
Setting range switching threshold for background suppression
E
Sensing range indicator
F
Teach-Turn adjustment
blue
Recommended sensing range for the best performance
Sensing range adjustment
WTB4FT-xxxxxx1xAxx
Adjustment via a potentiometer:
Clockwise rotation: Sensing range increased.
Counterclockwise rotation: Sensing range reduced.
WTB4FT-xxxxxx2xAxx
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.).
Depending on the requirements, the potentiometer can be used for fine-tuning (without
pressing the teach-in button).
Clockwise rotation: Sensing range increased.
Counterclockwise rotation: Sensing range reduced.
The sensing range can also be adjusted using just the potentiometer.
Dimensions in mm (inch)
15
(0.59)
12
(0.47)
9
(0.35)
6
(0.24)
3
(0.12)
0
–3
10
130
220
(–0.12)
0
20
(0.39)
(5.12)
(8.66)
(0.79)
Recommended sensing range for
the best performance
Figure 7: Vertical light spot size
40
60
80
100
120
10
50
(1.57)
(2.36)
(3.15)
(3.94)
(4.72)
(0.39)
(1.97)
Distance in mm (inch)
8025300.1BBX / 2021-05-12 | SICK
Subject to change without notice
Apex angle 4°
120
(4.72)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wtb4f

Tabla de contenido