Learning "Start" Opening Command Times - EB TECHNOLOGY START-S3XL-K Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

START-S3XL-K
5.1

Learning "START" OPENING COMMAND times

ON
1
2
3
4
1
2
3
4
5
2
led L1
3
4
5A
5B
6
7
8A
8B
8C
9
ON
10
1
2
3
4
5
If the times learning procedure with the START command has been performed correctly, the automation decele-
rates approximately 2 sec before reaching the full opening stroke while, in closing mode, it decelerates from the
selected point or after the "limit switch close" cuts in (see step 8 a/b/c in the table in chapter 5.1).
Turn off the circuit board
Set switch DIP 1 to ON
Power the control unit;
LED L1 is turned on when the control panel is programming
Press START (everything connected to input 16 or the 1st channel
of the compatible remote control that has been learned)
If you wish to activate the signal light in PAUSE : whe the gate is
opening, give a pedestrian command ( output no.17 or 2nd channel
of the remote control) otherwise read step no.5A
If LSO is not available, when the gate is at the end of the stroke,
press START
If the limit switch is connected you do not need to do anything
because the limit switch itself gives the programming input
Let the time elapse during which the automation
must remain open
Press START to start closing
On SLIDING, press START to defi ne the point in which the
automation is to slowing down
For roll-up-doors without LSC, press START to defi ne the slowing
down point.
For roll-up doors with LSC don't do anything as the slowing down
will be activated after 2 sec after intervention of the LSC
Wait for the automation to stop automatically
Set the switch DIP1 to OFF to return to standard mode,
the fl ashing light goes off and the TEST light goes back on
-13-
Technical Manual
The automation
is in the
CLOSED
position.
The automation
starts
OPENING
ACTIVATING the
FLASHING
LIGHT in
PAUSE MODE
The automation
STOPS
This is the
automation
"PAUSE TIME"
The automation
starts in
CLOSING mode
The automation
SLOW DOWN
The automation
is in the CLOSED
position
Time
programming
has been
completed

Publicidad

Capítulos

Tabla de contenido
loading