4

Managing of REMOTE CONTROL

To manage remote controls, the electronic circuit board must have a wireless module. The electronic circuit board
can handle several types of code, the fi rst remote control learned determines the type and, as a result, it is not
possible to learn remote controls with codes that diff er from that of the fi rst remote control learned. The codes that
can be handled are the 12 to 64 bit standards and, for rolling HCS© type codes, only the fi xed part but not the rolling
counter control. The fi rst transmitter learned determines the type of code that the receiver can handle; consequently
the subsequent transmitters learned must have the same type of code.
YOU CAN ACTIVATE OR DEACTIVATE THE COMPLETE ROLLING CODE FUNCTION. PRESS THE BUTTON WHEN YOU ARE
LEARNING THE PARTIAL OPENING COMMAND. THE L.E.D. WITH PARTIAL ROLLING CODE WILL FLASH
ONE TIME WHILE WHILE WHEN THE ROLLING CODE IS COMPLETE THE L.E.D. FLASHES TWICE.
4.1

Activation of the radio receiver

Bring the JUMPER as shown in
the picture
J-R
4.2

DELETING the codes memory

This operation deletes all codes in the memory. There is no arrangement for deleting single codes. The memory
must be reset before learning the fi rst remote control so that there are no previously learned codes and no unused
codes in the system. The memory, and thus all the codes, can be deleted when the automation is closed.
ON
1
1
2
3
4
5
15 secondi
>
2
P
L1
3
P
L1
Make sure that DIP switch 1 is set to OFF.
The automation is in the CLOSED position
Press the push-button P on the circuit board and keep it pressed for 15 seconds until
the TEST light starts fl ashing. The TEST light and the green START and PED lights go
on.The TEST light starts fl ashing
After 15 seconds, release push-button P on the circuit board.
Wait until the TEST light returns to normal fl ashing.