Increasing The Pause Time; Reset At Factory Settings; Problems Solution - EB TECHNOLOGY START-S3XL-K Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

START-S3XL-K
5.4

Increasing the PAUSE time

The pause time can be increased without having to repeat the times learning operation. While the automation is in
pause mode, each time the push-button P is pressed the pause time is increased by 5 seconds. The level can be
increased four times. The fi fth time the push-button is pressed, the pause time returns to the initial value (the L1
light goes on for a more an extended period of time). Therefore, it is possible to increase the pause time by up to 20
seconds (e.g. pressing the button 4 times x 5 seconds each). If 20 seconds is not enough, it is possible to continue
increasing the pause time by performing another opening cycle.
!
The operation can only be performed
when the automation is in pause mode
during opening
5.5

RESET at FACTORY SETTINGS

You can reset the control panel at factory's settings:
ON
1
1
2
3
4
5
4
2
ON
3
4
2
3
4
1
5
6
Problem solutions
PROBLEM:
The electronic circuit board does not work (the
TEST signal light does not fl ash).
SOLUTION:
Check the 4A and 160mA fuses.
PROBLEM:
The 160mA fuse is burnt out.
SOLUTION:
Check the connections and make certain that the
total power absorbed by the accessories does not
exceed 500mA.
PROBLEM:
The 4A fuse is burnt out.
SOLUTION:
Check the connections and the motor function,
fl ashing of the courtesy light.
PROBLEM:
The motor stops or nearly stops after a few seconds.
SOLUTION:
Try to increase the motor force (see chap.5.3) and
deactivate the slowing down.
Put DIP1 in ON
Keep pressed the button P until the LED is fl ashing longer
Bring DIP 1 in OFF position again
Time changing
each time the
button is pressed
PROBLEM:
The control panel works uncorrectly
SOLUTION: Try to increase the speed of slowing down with dip
switches 11 and 12
PROBLEM:
The control panel doesn't open
SOLUTION: Ccheck all red led . All must be lit on. If you use LS ,
LSC is turned on while the gate is closing. The green led have to
be turned off . If you don't use the input for safety edge, make a link
betwenn 22 and 23.
PROBLEM:
If you use the slowing down, the gate doesn't reach the stroke.
SOLUTION:
ke sure all services and safety connections are correctly con-
nected to one pole of the power supply. IMPORTANT: if you use
the 3 wire connection for photobeams we recommend to power at
12Vdc in the terminals 10 and 11 ( see chap. 2.6)
-15-
Technical Manual
+ 5s
+ 5s
+ 5s
+ 5s
L1
Initial time

Publicidad

Capítulos

Tabla de contenido
loading