START-S3XL-K
2.12

Connect the 3 WIRES PHOTO-BEAM

8
9 10 11 12 13 14 15 16 17 18 19
-
POWER SUPPLY
RX PHOTOCELL
+
N.C. contact terminals
-
2.13

Connection of the "START" and "PEDESTRIAN" commands

8
9 10 11 12 13 14 15 16 17 18 19
2.14

Checking connections

The TEST light signals that the internal logic is functioning correctly. It must fl ash at one second intervals indicating
that the internal microprocessor is on and awaiting a command. When the control unit is powered, the warning
lights, set on the inputs, are ON when the contacts on the inputs are closed toward the common:
Normally the red lights on inputs STOP - PHOTO - LSO - LSC - STOP - ALT are ON
Normally the green lights on the control inputs START - PEDESTRIAN are OFF
STOP
+
Photocell receiver.
The PEDESTRIAN (partial opening command) can be connected to
any push-button or N.O. (normally open) contact. If several devices
are used, they must be connected.
Using terminals 9 and 16 it is possible connect a TIMER to program
gate opening. The timer contact must be an NO (normally open) con-
tact and must remain closed for as long as the gate remains open.
If an opening command is connected to terminal 16, it must be con-
nected in parallel.
PHOTO
LSO
+
-
POWER SUPPLY
TX PHOTOCELL
The START opening command can be connected to
any push-button or N.O. (normally open) contact.
LSC
START
PED
-9-
Technical Manual
Bring JUMPER AC/DC
as shown in the picture
Voltage: 24 Vdc
Maximum current: 300 mA
ALT
Safety edge