Fault Diagnosis; In The Event Of Faults Or Errors; Sick Support - SICK TR4 Instrucciones De Operación

Ocultar thumbs Ver también para TR4:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
Chapter 8
8

Fault diagnosis

WARNING
WARNING
160
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Fault diagnosis
This chapter describes how to identify and remedy errors and malfunc-
tions during the operation of the TR4 safety switch.
8.1

In the event of faults or errors

Cease operation if the cause of the malfunction has not been clearly
identified!
Stop the machine if you cannot clearly identify or allocate the error
and if you cannot safely rectify the malfunction.
Do not attempt to repair the TR4 safety switch.
Replace faulty devices prior to placing the machine back in opera-
tion.
Behavior in case of recoverable errors:
In the case that recoverable errors occur (see Tab. 4 in section 8.3
"Error displays of the LED" on page 161), LED
the OSSDs Out A and Out B for short-circuit to 0 V, 24 V DC or to each
other and rectify this error without delay.
Check the cabling for damage, i.e. whether the two-channel
functionality is still present.
8.2

SICK support

If you cannot rectify an error with the help of the information provided
in this chapter, please contact your local SICK representative.
Operating Instructions
TR4
Red (1Hz)), check
8014465/2012-05-07
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido