Basic User Interface (U0)
37
30
36
38
31
40
34
Figure 7
30. Display:
Left display: Shows wire feed speed or welding
current. During welding shows the actual welding
current value.
Right display: Shows the welding voltage in volts
units. During welding shows the actual welding
voltage value.
31. Left Control: Adjusts values on the Left display.
32. Right Control: Adjusts values on the Right display.
33. Right Button: Enables scrolling, changing and setting
welding parameters.
34. Left Button: Enables changing the welding process.
35. Thermal Overload Indicator: It indicates that the
machine is overloaded or that the cooling is not
sufficient.
36. Status LED: A two color light that indicates system
errors. Normal operation is steady green light. Error
conditions are indicated, per Table 1.
WARNING
The status light will flash green, and sometimes red and
green, for up to one minute when the machine is first
turned on. When the power source is powered it can take
as long as 60 seconds for the machine to be ready to
weld. This is a normal situation as the machine goes
through initialization.
English
35
30
39
32
41
33
Table 1 LED Light Conditions
LED Light
Only machines which using CAN
Condition
protocol for communication
Correct operation mode. The power
Steady Green
source communicates normally with
all peripheral equipment.
Occurs during a system reset, and
indicates that the power source is
mapping
connected
system.
Blinking Green
This
seconds after connecting the power
supply
configuration
operation.
If the status lights are flashing any
combination of red and green color, it
means that an error is present in the
machine.
Each digit of the code represents the
number of red flashes of the indicator
light.
flashed in red with a long pause
between digits. If more than one code
Alternating
is
Green and Red
separated by green light. Read the
error code before you turn of the
machine.
To clear the error, turn off the
machine, wait a few seconds, and
then turn on the machine again. If the
error remains, a maintenance is
required. Please contact the nearest
authorized service center or Lincoln
Electric and report the error code.
Indicate no communication in CAN
Steady Red
protocol.
37. LED Indicator: Informs that the left display shows the
wire feed speed.
38. LED Indicator: Informs that the left display shows the
ampere units.
39. LED Indicator: Informs that the right display shows
the volts units.
40. Welding Programs Indicators: LED light indicate the
active manual weld mode. See Table 2.
41. Welding Parameters Indicators: LED light indicate
the active weld parameters. See Table 3.