Welding process change
It is possible to quick recall of one of the six manual
welding programs - Table 2.
Table 2 Manual Weld Modes:
Symbol
LED
GMAW
FCAW
SMAW
To set the welding process:
Press the left button [34], to select the right weld mode
– LED of the current program flashes.
Again press the left button, the active weld mode
indicator will skip to the next program.
WARNING
During switching the displays show a "dotted line" on the
screen.
English
Process
GMAW MIX
GMAW CO
2
GMAW AR
FCAW MIX
FCAW CO
2
SMAW
13
Quick Access and Configuration Menu
for U0 User Interface
Users have access to the two menu levels:
Quick Access – basic menu related with welding
parameters settings
Configuration Menu – pro menu associated with
machine
configuration
parameters.
WARNING
Access to the menu is not available under welding, or if
there is a fault (status LED is not solid green).
Availability of the parameters in the Quick Access and
Configuration Menu depend on the selected welding
program / welding process.
After the device has been restarted the user settings are
restored.
Parameter Selection Mode – the parameter name on the
left display [30] blinking.
Parameter Change Value Mode – the parameter value
on the right display [30] blinking.
Basic level
To enter the menu (Table 3):
Press the right button [33] to select mode.
Use the right knob [32] to set the value of parameter.
Press the left button [34], to return to main menu.
WARNING
System returns to the main menu automatically after 2
seconds of inactivity.