Installation And Initial Operation - oventrop TRV9 Manual De Instrucciones

Ocultar thumbs Ver también para TRV9:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6 Installation and initial
operation
The thermostatic valve and the radiator
lockshield valve must only be installed into
a clean pipework system and must only be
operated with a clean unpolluted fluid.
6.1 Installation
6.1.1 Installation of the thermostatic valve
The thermostatic valve is installed in the
supply pipe to the radiator so that the
thermostat is in a horizontal position and a
good circulation of air is guaranteed.
NOTICE
To avoid rattling noises, the direction of
flow in the supply pipe has to conform to
the direction of the arrow on thermostatic
valve.
6.1.2 Installation of the radiator
lockshield valve
The radiator lockshield valve is installed in
the return pipe of the radiator. The isolating
facility has to be easily accessible.
6.1.3 Pipework
standardized metal and plastic
pipes
Oventrop
offers
for different types of connection (e.g.
screwed
connection)
copper, stainless steel, precision steel and
plastic pipes to the thermostatic valve
and radiator lockshield valve (accessories,
see catalogue Connection system "Ofix").
Threaded steel pipes are directly mounted
onto the thermostatic valve and the radiator
lockshield valve.
installation
for
connection
elements
of
standardized
NOTICE
When using compression fittings for
female threaded radiator fittings (sized
DN 10, 15, 20), the "Ofix" compression
fittings have to be used to guarantee
a perfect sealing function between the
pipework and the valve.
Item no. 10271../10281..
1. Cut the pipe to the required length at a
right angle to the tubular axle.
2. When using thin walled or very soft
pipes, the pipe ends have to be
equipped
with
(accessories)
before
compression fitting. The reinforcing
sleeve provides the strength to enable
the necessary compression and a tight
pipe/valve connection is guaranteed.
3. Reinforcing
sleeves
used on pipes with welded seams.
The recommendations of the pipe
manufacturer must be observed. Check
if the function of the compression fitting
is guaranteed.
NOTICE
Do not use any greasing agents or oil for
the installation, as these can destroy the
valve seals.
The individual components are lubricated
at works.
reinforcing
sleeves
installing
the
cannot
be
13

Publicidad

Tabla de contenido
loading

Tabla de contenido