Connect the stapler unit to the compressed air
supply
You can connect the stapler unit to a compressor or a compressed
air system. (only valid for air-powered stapler units)
Operation with a compressor or a compressed air system is
permitted only under the following conditions:
 The operating pressure of the compressor or compressed air
system must be no more than 10% above the maximum operating
pressure of the stapler unit. You can find information on the
operating pressure of the stapler unit in this chapter on page 19.
 In compressed air systems with a higher pressure, a pressure-
regulating valve (pressure reducing valve) with a downstream
pressure-limiting valve must be installed in the compressed air
supply.
 Compressed air must be filtered to be dry and lubricated with
special PREBENA nailer oil.
 A compressed air maintenance unit must be mounted on the
clutch side at the suspension of the compressed air line to the
stapler. This should contain
-
a filter,
-
a water separator and
-
an oiler.
 When using hose lengths over 10 m, it is not guaranteed that the
drive-in device will be supplied with oil. We therefore recommend
to add on working days two to five drops of the recommended oil
into the air inlet of the device or to install a lubricator directly on
the drive-in device.
 The compressed air system must also be able to maintain the
operating pressure at the desired air extraction.
 The inner diameter of the air duct should be at least 8 mm.
 The connector for the stapler must be equipped with a quick
coupling with NW 7.2 and with at least 6.5 mm inner diameter