Electrical Connections - Sime BRAVA SLIM HE ErP Serie Manual De Instalation Y Mantenimiento

Calderas murales de condensación
Ocultar thumbs Ver también para BRAVA SLIM HE ErP Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Load loss accessory Ø 60 mm
Description
Code
Air/smoke split
8093060
pipe system
90° curve MF
8089921
45° curve MF
8089922
Horizontal
extension W. 1000
8089920
mm
Vertical extension
8089920
W. 1000 mm
Wall outlet
8089541
terminal
Wall inlet terminal 8089540
Roof outlet
8091204
terminal (*)
(*) The losses of the roof outlet terminal at inlet include the
manifold code 8091400.
for the boiler to operate correctly it is necessary that a
NOTE:
minimum distance of 0.50 m of the duct is respected with a 90°
inlet curve.
Load loss accessory Ø 80 mm
Description
Code
90° curve MF
8077450
45° curve MF
8077451
Horizontal
extension W. 1000
8077351
mm
Vertical extension
8077351
W. 1000 mm
Wall terminal
8089501
Roof outlet
8091204
terminal (*)
Description
Code
90° curve MF
8077450
45° curve MF
8077451
Horizontal
extension W. 1000
8077351
mm
Vertical extension
8077351
W. 1000 mm
Wall terminal
8089501
Roof outlet
8091204
terminal (*)
(*) The losses of the roof outlet terminal at inlet include the
manifold code 8091400.
for the boiler to operate correctly it is necessary that a
NOTE:
minimum distance of 0.50 m of the duct is respected with a 90°
inlet curve.
78
Load loss (mm H
O)
2
Brava Slim HE
Brava Slim HE
35 ErP
40 ErP
Inlet
Outlet
Inlet
Outlet
2,5
0,5
2,5
0,5
0,6
1,4
0,6
1,4
0,55
1,2
0,55
1,2
0,6
1,4
0,6
1,4
0,6
0,8
0,6
0,8
_
1,6
_
1,6
1,1
_
1,1
_
1,5
0,2
1,5
0,2
Load loss (mm H
O)
2
Brava Slim HE
Brava Slim HE
25 ErP
30 ErP
Inlet
Outlet
Inlet
Outlet
0,20
0,25
0,25
0,30
0,15
0,15
0,20
0,20
0,15
0,15
0,20
0,20
0,15
0,15
0,20
0,20
0,10
0,25
0,10
0,35
0,80
0,10
1,10
0,15
Load loss (mm H
O)
2
Brava Slim HE
Brava Slim HE
35 ErP
40 ErP
Inlet
Outlet
Inlet
Outlet
0,30
0,4
0,30
0,4
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,15
0,50
0,15
0,50
1,5
0,2
1,5
0,2
Example: calculation of the load loss of a Brava Slim HE 25 ErP
boiler.
Accessories Ø 80
Code
Quantity
mm
Extension W. 1000
8077351
mm (horizontal)
Extension W. 1000
8077351
mm (horizontal)
90° curve
8077450
90° curve
8077450
Wall terminal
8089501
TOTAL
(installation permitted since the total of the load loss of the
accessories used is less than 15 mmH
2.13

Electrical connections

The boiler is equipped with a ready wired power cable which is
to be connected to a 230V~50 Hz network.
If this cable needs to be replaced, an original spare must be
requested from Sime .
Therefore only the connections of the original components
as shown in the table are needed. These are to be ordered
separately from the boiler.
DESCRIPTION
External sensor kit (ß=3435, NTC 10KOhm at 25°C)
Power cable (dedicated)
Remote control HOME (open therm)
Remote control HOME PLUS (open therm)
m
CAUTION
The maintenance interventions described must ONLY
be carried out the professionally qualified personnel.
EN
Load loss (mm H
O)
2
Inlet
Outlet
Total
7
7 x 0,15
-
1,05
7
-
7 x 0,15
1,05
2
2 x 0,20
-
0,40
2
-
2 x 0,25
0,50
2
0,10
0,25
0,35
3,35
O).
2
400
250
120
Fig. 17
CODE
8094101
6323875
8092280
8092281

Publicidad

Tabla de contenido
loading

Tabla de contenido