Text
Description
code
Monitoring
1
No additional monitoring, for example dry-running protection, is required for the pump system.
If the operator cannot ensure that the pump is filled with pumped liquid during operation, appropriate
2
monitoring, for instance dry-running protection, is required to stop the pump in case of malfunction.
3
No additional monitoring, for example dry-running protection, is required for the auxiliary unit.
If the operator cannot ensure that the auxiliary unit is filled with barrier or flushing liquid during
4
operation, appropriate monitoring, for instance a level switch, is required to give an alarm in case of
malfunction.
5
In case of a drop in barrier liquid pressure, a warning must be given. Check the system and remedy.
In case of a drop in barrier liquid pressure, an alarm must be given, and the system must shut down if
6
the barrier liquid pressure is not brought back to the correct pressure level.
Circulating liquid
If circulation of the barrier or flushing liquid is lost, a warning must be given. Check the system and
7
remedy.
If circulation of the barrier or flushing liquid is lost, an alarm must be given. Check the system and
8
remedy. The system must shut down if the circulation cannot be re-established during operation.
Ventilation
10
Ventilation around the pump is not required.
The leakage rate of a normally working shaft seal is less than 36 ml for each 24 hours of operation.
11
Ventilation around the pump is required. The minimum air exchange is 1.5 times per hour.
CAUTION
Flammable material
Minor or moderate personal injury
- The responsibility for checking the
functions of the dry-running protection,
such as flow rate, sealing pressure and
temperature of the barrier or flushing
liquid, rests with the installer or owner.
11